USG6320-BDL-AC Specification
|
Type
|
USG6320 AC Host (8 GE (RJ45), 2 GB Memory, with IPS-AV-URL Function Group Update Service Subscribe 12 Months)
|
IPv4 Firewall Throughput1 (1,518/512/64-byte , UDP )
|
2 Gbit/s, 2 Gbit/s, 0.4 Gbit/s
|
IPv6 Firewall Throughput1 (1,518/512/84-byte , UDP)
|
2 Gbit/s, 2 Gbit/s, 0.4 Gbit/s
|
Firewall Throughput (packets per second)
|
0.6 Mpps
|
Firewall Latency (64-byte, UDP)
|
35 µs
|
FW + SA* Throughput2
|
1.2 Gbit/s
|
FW + SA + IPS Throughput2
|
700 Mbit/s
|
FW + SA + Antivirus Throughput2
|
700 Mbit/s
|
FW + SA + IPS + Antivirus + URL Throughput2
|
500 Mbit/s
|
FW+SA+IPS+Antivirus Throughput (real world)3
|
400 Mbit/s
|
Concurrent Sessions (HTTP1.1)1
|
500,000
|
New Sessions/Second (HTTP1.1)1
|
20,000
|
IPsec VPN Throughput1 (AES-128 + SHA1, 1,420-byte)
|
600 Mbit/s
|
Maximum IPsec VPN Tunnels (GW to GW)
|
2,000
|
Maximum IPsec VPN Tunnels (client to GW)
|
2,000
|
SSL Inspection Throughput4
|
15 Mbit/s
|
SSL VPN Throughput5
|
40 Mbit/s
|
Concurrent SSL VPN Users (default/maximum)
|
100/200
|
Security Policies (maximum)
|
3,000
|
Virtual Firewalls (default/maximum)
|
10/20
|
High Availability Configurations
|
Active/Active, Active/ Standby
|
URL Filtering: URLs
|
Can access a database of over 120 million URLs in the cloud
|
Third-Party and Open-Source Ecosystem6
|
Open APIs for integration with third-party products through RESTCONF and NETCONF interfaces Other third-party management software based on SNMP, SSH, and syslog Collaboration with third-party tools, such as FireMon
|
Centralized Management
|
Centralized configuration, logging, monitoring, and reporting is performed by Huawei eSight and LogCenter
|
VLANs (maximum)
|
4,094
|
Virtual Interfaces (maximum)
|
1,024
|
Dimensions (H x W x D)
|
44.5 mm x 300 mm x 220 mm
|
Form Factor/Height
|
Desktop
|
Fixed Interfaces
|
8 x GE (RJ45)
|
USB 2.0 Port
|
Supported
|
4G LTE
|
The USB port houses a 4G LTE data card
|
MTBF
|
19.06 years
|
Weight (full configuration)
|
1.58 kg
|
Power Consumption (average/maximum)
|
23.2W/28.5W
|
Heat Dissipation
|
97 BTU/h
|
Noise
|
48 dBA
|
Power Supplies
|
External Power Adapter, 36W
|
AC Power Supply
|
100V to 240V, 50 Hz/60 Hz
|
Operating Environment (temperature/humidity)
|
Temperature: 0°C to 45°C Humidity: 5% to 95%, non-condensing
|
Non-operating Environment
|
Temperature: -40°C to 70°C Humidity: 5% to 95%, non-condensing
|
Operating Altitude (maximum)
|
5,000 meters
|
Non-operating Altitude (maximum)
|
5,000 meters
|
Software
|
ICSA Labs: Firewall, IPS, IPsec, and SSL VPN CC: EAL4+
|
Hardware
|
CB, CCC, CE-SDOC, ROHS, REACH & WEEE (EU), RCM, ETL, FCC & IC, VCCI, and BSMI (USG6320)
|
Regulatory Compliance
|
Products comply with CE markings per directives 2014/30/EU and 2014/35/EU
|
Safety
|
UL 60950-1 CSA-C22.2 No. 60950-1 EN 60950-1 IEC 60950-1 GB4943.1
|
EMC: Emissions
|
AS/NZS CISPR 22 CISPR 22 Class B EN 55022 Class B ETSI EN 300 386 ETSI EN 301 489 (USG6305-W/6310S-W/6310S-WL-OVS) IEC 61000-6-3/EN 61000-6-3 IEC 61000-6-4/EN 61000-6-4 IEC 61000-3-2/EN 61000-3-2 IEC 61000-3-3/EN 61000-3-3 FCC CFR47 Part 15 Subpart B Class B ICES-003 Class B VCCI V-3 Class B CNS 13438 Class B (USG6320) GB9254 Class B
|
EMC: Immunity
|
EN 55024 CISPR 24 ETSI EN 300 386 ETSI EN 301 489 (USG6305-W/6310S-W/6310S-WL-OVS) IEC 61000-6-1/EN 61000-6-1 IEC 61000-6-2/EN 61000-6-2 CNS 13438 Class B (USG6320) YD/T993
|