Overview Of 9000-P12
No Data FoundSpecification Of 9000-P12
9000-P12 Datasheet
9000-P12 Specification
9000-P12 Â Specifications |
|
Hardware Specifications |
|
System architecture |
Fully symmetrical distributed architecture |
Number of nodes |
3 to 288 |
CPUs per node |
2 x Intel E5 series |
NVDIMM |
2 GB NVDIMM |
Cache per node |
Standard configuration: 32 GB, scalable to 192 GB |
Data disk type |
3.5-inch SSD, SATA disks, and NL-SAS disks |
Number of disks per node |
Standard configuration: 12 x 3.5-inch 2 TB/4 TB/6 TB/8 TB/10 TB SATA or 2 TB/4 TB NL-SAS (The SSD/ HDD configuration ratio can be adjusted based on actual performance requirements.) |
Software |
Dynamic storage tiering (InfoTier) Automatic load balancing of client connections (InfoEqualizer) Space quota management (InfoAllocator) Snapshot (InfoStamper) WORM (InfoLocker) Remote replication (InfoReplicator) Surveillance video and imagery restoration (SecureVideo) |
Front-end network type |
10GE, InfiniBand, and 1GE |
Internal network type |
10GE and InfiniBand |
Application Scenarios |
Large-capacity and highbandwidth |
Software Features |
|
Data protection level |
N+1, N+2, N+3, N+4 (Data is still usable even if 4 nodes failed.) |
File system |
OceanStor DFS, which supports the global namespace and can be dynamically expanded up to 100 PB |
Value-added object storage feature |
Object-level deduplication Multi-tenant HTTPs Encrypted transmission |
Thin provisioning |
Support for thin provisioning, which does not need to be configured |
Data self-healing |
Automatic, concurrent, and quick data restoration, with maximum restoration speed at 1 TB/hour |
System expansion |
One-click online expansion, with less than 60 seconds needed for expansion of a single node |
Global cache |
Up to 55 TB of global cache |
Operating system |
Windows, Linux, UNIX, and Mac OS |
Supported protocols |
NFS, CIFS, FTP, HDFS, S3/Swift, NDMP, NIS, Microsoft Active Directory, and LDAP |
System management |
Support for users with different management rights, and domain- and rights-based user management Alarm notification by email, SMS, SNMP, and Syslog |
Bad disk detection |
Automatic bad disk detection and alarm notification as well as batch replacement of bad disks, avoiding the need for immediate replacement while freeing up maintenance personnel to handle more pressing tasks. |
Physical Specifications |
|
Power supply |
200 V AC to 240 V AC |
Dimensions (H x W x D) |
2 U, 86.1 mm x 446 mm x 582 mm (3.39 in. x 17.56 in. x 22.91 in.) |
Cabinet: Maximum size: 2000 mm x 600 mm x 1200 mm (78.4 in. x 23.62 in. x 47.24 in.) |
|
Weight |
Fully loaded with 3.5-inch disks: ≤ 32 kg (71 lb.) |
Typical power |
260 W |
Operating temperature |
5ºC to 35ºC (41ºF to 95ºF) when the altitude ranges from –60 m to +1,800 m (–196.85 ft to +5,905.44 ft) When the altitude is higher than 1,800 m (5,905.44 ft) but lower than or equal to 3,000 m (9,842.4 ft), the ambient temperature drops by 0.6ºC (1.08ºF) for every 100-m (328.08-ft) increment in altitude. |
Operating humidity |
20% RH to 80% RH |