huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • CE12816-AC

    CE12816 AC Assembly Chassis(with CMUs and Fans)
  • List Price:

      $36,000 (59% OFF)

  • $14,760
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • CE12816-AC Specification

    CE12816AC Specifications

    Switching Capacity 
    (Tbit/s)

    178/
    1,032

    Forwarding Rate 
    (Mpps)

    69,120

    Service Slots

    16

    Switching Fabric 
    Module Slots

    6

    Fabric Architecture

    Clos architecture, cell switching, VoQ, and distributed large buffer

    Airflow Design

    Strict front-to-back

    Device Virtualization

    Virtual System (VS)

    Cluster Switch System (CSS)2

    Super Virtual Fabric (SVF)3

    Network Virtualization

    M-LAG

    TRILL

    VxLAN routing and bridging

    EVPN

    QinQ in VXLAN

    VM Awareness

    Agile Controller

    Network Convergence

    FCoE

    DCBX, PFC, and ETS

    Data Center Interconnect

    BGP-EVPN

    Ethernet Virtual Network (EVN) for inter-DC Layer 2 network interconnections

    Programmability

    OpenFlow

    ENP programming

    OPS programming

    Puppet, Ansible, and OVSDB plug-ins released on open source websites

    Linux container for open source and customization programming

    Traffic Analysis

    NetStream

    Hardware-based sFlow

    VLAN

    Adding access, trunk, and hybrid interfaces to VLANs

    Default VLAN

    QinQ

    MUX VLAN

    GVRP

    MAC Address

    Dynamic learning and aging of MAC addresses

    Static, dynamic, and blackhole MAC address entries

    Packet filtering based on source MAC addresses

    MAC address limiting based on ports and VLANs

    IP Routing

    IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP

    IPv6 routing protocols, such as RIPng, OSPFv3, ISISv6, and BGP4+

    IP packet fragmentation and reassembling

    IPv6

    IPv6 over VXLAN

    IPv6 over IPv4

    IPv6 Neighbor Discovery (ND)

    Path MTU Discovery (PMTU)

    TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6

    Multicast

    IGMP, PIM-SM, PIM-DM, MSDP, and MBGP

    IGMP snooping

    IGMP proxy

    Fast leave of multicast member interfaces

    Multicast traffic suppression

    Multicast VLAN

    MPLS

    Basic MPLS functions

    MPLS VPN/VPLS/VPLS over GRE

    Reliability

    Link Aggregation Control Protocol (LACP)

    STP, RSTP, VBST, and MSTP

    BPDU protection, root protection, and loop protection

    Smart Link and multi-instance

    Device Link Detection Protocol (DLDP)

    Ethernet Ring Protection Switching (ERPS, G.8032)

    Hardware-based Bi-directional Forwarding Detection (BFD)

    VRRP, VRRP load balancing, and BFD for VRRP

    BFD for BGP/IS-IS/OSPF/Static route

    In-Service Software Upgrade (ISSU)

    Segment Routing (SR)

    QoS

    Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information

    Actions include ACL, CAR, and re-marking

    Queue scheduling modes such as PQ, WFQ, and PQ + WRR

    Congestion avoidance mechanisms, including WRED and tail drop

    Traffic shaping

    O&M

    IEEE 1588v2

    Packet Conservation Algorithm for Internet (iPCA)

    Dynamic Load Balancing (DLB)

    Dynamic Packet Prioritization (DPP)

    Network-wide path detection

    Microsecond-level buffer detection

    Configuration 
    and Maintenance

    Console, Telnet, and SSH terminals

    Network management protocols, such as SNMPv1/v2c/v3

    File upload and download through FTP and TFTP

    BootROM upgrade and remote upgrade

    Hot patches

    User operation logs

    Zero-Touch Provisioning (ZTP)

    Security 
    and Management

    802.1x authentication

    RADIUS and HWTACACS authentication for login users

    Command line authority control based on user levels, preventing unauthorized users from using commands

    Defense against MAC address attacks, broadcast storms, and heavy-traffic attacks

    Ping and traceroute

    Remote Network Monitoring (RMON)

    Dimensions 
    (W x D x H, mm)

    442 x 
    905 x 
    1,597.4
    (36 U)

    Chassis Weight (empty)

    < 290 kg
    (639 lb)

    Operating Voltage

    AC: 90V to 290V
    DC: -38.4V to -72V
    HVDC: 240V

    Max. Power Supply

    30,000W

    ]
  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
CE12816-AC

CE12816 AC Assembly Chassis(with CMUs and ...

Price: $14,760
List Price: $36,000 (59% OFF)
Overview Specification Support Warranty

Overview Of CE12816-AC

No Data Found

Specification Of CE12816-AC

CE12816-AC Datasheet

CE12816-AC Specification

CE12816AC Specifications

Switching Capacity 
(Tbit/s)

178/
1,032

Forwarding Rate 
(Mpps)

69,120

Service Slots

16

Switching Fabric 
Module Slots

6

Fabric Architecture

Clos architecture, cell switching, VoQ, and distributed large buffer

Airflow Design

Strict front-to-back

Device Virtualization

Virtual System (VS)

Cluster Switch System (CSS)2

Super Virtual Fabric (SVF)3

Network Virtualization

M-LAG

TRILL

VxLAN routing and bridging

EVPN

QinQ in VXLAN

VM Awareness

Agile Controller

Network Convergence

FCoE

DCBX, PFC, and ETS

Data Center Interconnect

BGP-EVPN

Ethernet Virtual Network (EVN) for inter-DC Layer 2 network interconnections

Programmability

OpenFlow

ENP programming

OPS programming

Puppet, Ansible, and OVSDB plug-ins released on open source websites

Linux container for open source and customization programming

Traffic Analysis

NetStream

Hardware-based sFlow

VLAN

Adding access, trunk, and hybrid interfaces to VLANs

Default VLAN

QinQ

MUX VLAN

GVRP

MAC Address

Dynamic learning and aging of MAC addresses

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

MAC address limiting based on ports and VLANs

IP Routing

IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP

IPv6 routing protocols, such as RIPng, OSPFv3, ISISv6, and BGP4+

IP packet fragmentation and reassembling

IPv6

IPv6 over VXLAN

IPv6 over IPv4

IPv6 Neighbor Discovery (ND)

Path MTU Discovery (PMTU)

TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6

Multicast

IGMP, PIM-SM, PIM-DM, MSDP, and MBGP

IGMP snooping

IGMP proxy

Fast leave of multicast member interfaces

Multicast traffic suppression

Multicast VLAN

MPLS

Basic MPLS functions

MPLS VPN/VPLS/VPLS over GRE

Reliability

Link Aggregation Control Protocol (LACP)

STP, RSTP, VBST, and MSTP

BPDU protection, root protection, and loop protection

Smart Link and multi-instance

Device Link Detection Protocol (DLDP)

Ethernet Ring Protection Switching (ERPS, G.8032)

Hardware-based Bi-directional Forwarding Detection (BFD)

VRRP, VRRP load balancing, and BFD for VRRP

BFD for BGP/IS-IS/OSPF/Static route

In-Service Software Upgrade (ISSU)

Segment Routing (SR)

QoS

Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information

Actions include ACL, CAR, and re-marking

Queue scheduling modes such as PQ, WFQ, and PQ + WRR

Congestion avoidance mechanisms, including WRED and tail drop

Traffic shaping

O&M

IEEE 1588v2

Packet Conservation Algorithm for Internet (iPCA)

Dynamic Load Balancing (DLB)

Dynamic Packet Prioritization (DPP)

Network-wide path detection

Microsecond-level buffer detection

Configuration 
and Maintenance

Console, Telnet, and SSH terminals

Network management protocols, such as SNMPv1/v2c/v3

File upload and download through FTP and TFTP

BootROM upgrade and remote upgrade

Hot patches

User operation logs

Zero-Touch Provisioning (ZTP)

Security 
and Management

802.1x authentication

RADIUS and HWTACACS authentication for login users

Command line authority control based on user levels, preventing unauthorized users from using commands

Defense against MAC address attacks, broadcast storms, and heavy-traffic attacks

Ping and traceroute

Remote Network Monitoring (RMON)

Dimensions 
(W x D x H, mm)

442 x 
905 x 
1,597.4
(36 U)

Chassis Weight (empty)

< 290 kg
(639 lb)

Operating Voltage

AC: 90V to 290V
DC: -38.4V to -72V
HVDC: 240V

Max. Power Supply

30,000W

]
Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies