huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • Huawei FusionServer RH5885H V3 Rack Server

    Huawei FusionServer RH5885H V3 Rack Server, Intel Xeon Intel Xeon E7 V2 or V3 series CPU, 96 DDR4 DIMMs, RAID, Energy efficiency, 5 hot-swappable fan modules, 2 hot-swappable power supplies
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • Huawei FusionServer RH5885H V3 Rack Server Specification

    Huawei FusionServer RH5885H V3 Rack Server Specifications

    Form factor/height

    4U rack server, supporting hold rails and cable management assemblies.

    Processor

    A maximum of four Intel® Xeon® E7-4800 or E7-8800 v2 (Ivy Bridge-EX) processors, with up to 15 cores and 37.5 MB L3 cache per processor.

    A maximum of four Intel® Xeon® E7-4800 or E7-8800 v3 (Haswell-EX) processors, with up to 18 cores and 45 MB L3 cache per processor.

    A maximum of four Intel® Xeon® E7-4800 or E7-8800 v4 (Broadwell-EX) processors, with up to 24 cores and 60 MB L3 cache per processor.

    Chipset

    Intel Patsburg PCH.

    DIMM slot

    96 slots for installing DDR3 or DDR4 DIMMs.

    There are 8 memory risers in total. Each processor supports two memory risers, and each memory riser supports 8 or 12 DIMMs.

    Maximum memory capacity

    6 TB (using 64 GB DIMMs).

    Hard disk tray

    8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.

    23 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.

    8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs + 4 x 2.5-inch scheduled hot-swappable NVMe PCIe SSDs.

    NOTICE:

    The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSDs and Intel NVMe PCIe SSDs at the same time.

    When Huawei ES3000 V3 NVMe PCIe SSDs are installed, upgrade the ES3000 V3 driver to the latest version.

    Maximum local storage capacity

    8 hard disks: 8 x 1.2 TB = 9.6 TB

    23 hard disks: 23 x 1.2 TB = 27.6 TB

    8 + 4 hard disks: 8 x 1.2 TB + 4 x 2 TB = 17.6 TB

    NOTE:

    The RH5885H V3 supports 8, 23, and 8 + 4 hard disk configurations.

    RAID

    A RAID controller card supports either of the following:

    RAID 0, 1, 10, and 1E

    RAID 0, 1, 10, 5, 50, 6, and 60, a maximum cache capacity of 2 GB, and a supercapacitor for power-off protection

    Network port

    The onboard NIC can be flexibly configured to provide either of the following ports:

    Four integrated GE 1000BASE-T ports

    Two 10GE optical ports

    Two GE electrical ports

    Expansion slot

    The RH5885H V3 supports a non-standard PCIe slot dedicated for a RAID controller card.

    The RH5885H V3 also supports various PCIe risers with different PCIe specifications:

    16 standard PCIe slots

    Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

    Eight PCIe 3.0 x8 slots for installing full-height full-length cards

    Two PCIe 3.0 x4 slots for installing full-height full-length cards

    Two PCIe 2.0 x4 slots for installing full-height full-length cards

    12 standard PCIe slots

    Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

    Four PCIe 3.0 x16 slots for installing full-height full-length cards

    Two PCIe 3.0 x4 slots for installing full-height full-length cards

    Two PCIe 2.0 x4 slots for installing full-height full-length cards

    14 standard PCIe slots

    Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

    Four PCIe 3.0 x8 slots for installing full-height full-length cards

    Two PCIe 3.0 x16 slots for installing full-height full-length cards

    Two PCIe 3.0 x4 slots for installing full-height full-length cards

    Two PCIe 2.0 x4 slots for installing full-height full-length cards

    NOTICE:

    The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSD cards and Intel NVMe PCIe SSDs at the same time.

    When Huawei ES3000 V3 NVMe PCIe SSD cards are installed, upgrade the ES3000 V3 driver to the latest version.

    External port

    Front panel: two USB 2.0 ports, one power button, one UID button, one video graphics array (VGA) port, and one touched diagnostic LCD.

    Rear panel: two USB 2.0 ports, one VGA port, one serial port, one 100 Mbit/s management port, one UID indicator, and one plug-in NIC.

    DVD-ROM drive

    One

    PSU

    The PSUs can be configured as follows:

    Two 3000 W AC PSUs in 1+1 redundancy mode

    Two 2000 W AC PSUs in 1+1 redundancy mode

    Two 2500 W DC PSUs in 1+1 redundancy mode

    Four 800 W AC PSUs in 2+2 redundancy mode

    System management

    IPMI/SNMP/CLI

    Security feature

    Power-on password and administrator password.

    Front bezel.

    Video card

    The system mainboard integrates the display chip and provides 16 MB display memory. The maximum resolution is 1024 x 768.

    Technical Specifications

    Chassis dimensions (H x W x D)

    175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)

    Installation space

    The server fits into a standard cabinet that complies with the IEC 297 standard:

    Width: 19 in.

    Minimum depth: 1000 mm (39.37 in.)

    The guide rails to be used vary with cabinets:

    Use L-shaped guide rails for a Huawei cabinet.

    Use adjustable guide rails if the distance between the front and rear mounting bars of a cabinet is 560 mm (22.05 in.) to 858 mm (33.78 in.).

    Use holding rails if the distance between the front and rear mounting bars of a cabinet is 610 mm (24.02 in.) to 914 mm (35.98 in.).

    Maximum weight

    8-bay server: 52 kg (114.66 lb)

    12-bay server: 53 kg (116.84 lb)

    23-bay server: 56 kg (123.48 lb)

    NOTE:

    Maximum weight

    Includes the weight of CPUs, DIMMs, and hard disks in full configuration.

    Does not include the weight of the package or PCIe cards.

    PCIe card weight

    Standard half-height half-length PCIe card: 0.3 kg (0.66 lb)

    Standard full-height half-length PCIe card: 0.4 kg (0.88 lb)

    Standard full-height full-length dual-slot PCIe card (for example, a GPU): 1 kg (2.21 lb)

    Package: 7 kg (15.44 lb)

    Temperature

    Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)

    Storage temperature: -40°C to +65°C (-40°F to +149°F)

    Maximum temperature change rate: 20°C/h (36°F/h)

    Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

    NOTE:

    If an SSD card or a GPU is configured, the maximum operating temperature is 35°C (95°F).

    Relative humidity (non-condensing)

    Operating humidity: 10% to 90%

    Storage humidity: 5% to 95%

    Maximum humidity change rate: 20%/h

    Long-term storage humidity: 30% RH to 69% RH (non-condensing)

    Altitude

    ≤ 3000 m (9842.40 ft)

    The highest operating temperature decreases by 1°C (1.8°F) with every increase of 300 m (984.24 ft) in an altitude above 900 m (2952.72 ft).

    At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used.

    HDDs are not supported at an altitude of over 3000 m (9842.5 ft).

    Acoustic noise

    The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

    Idle:

    LWAd: 7.1 Bels

    LpAm: 58.8 dBA

    Operating:

    LWAd: 7.1 Bels

    LpAm: 58.8 dBA

    NOTE:

    The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

    Corrosive air pollutant

    Corrosion rate of the copper test piece: < 300 Ã…/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)

    Corrosion rate of the silver test piece: < 200 Ã…/month

    Particulate pollutant

    The ISO14664-1 Class 8 requirements are met.

    You are advised to ask a professional organization to monitor particulate pollutants in the equipment room.

    There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

    Input voltage

    Two PSUs:

    2500 W DC PSUs: –48 V DC to –60 V DC

    2000 W AC PSUs:

    100 V AC to 240 V AC, 50 Hz/60 Hz

    240 V DC

    3000 W AC PSUs:

    100 V AC to 240 V AC, 50 Hz/60 Hz

    240 V DC

    Four PSUs:

    800 W AC PSUs:

    100 V AC to 240 V AC, 50 Hz/60 Hz

    240 V DC

    NOTE:

    Recommended current for external circuit breakers:

    DC: 63 A

    AC: 32 A

    380 V HVDC: 32 A

    Input current

    DC PSUs: 63 A

    AC PSUs: 10 A or 16 A

    HVDC PSUs: 10 A or 16 A

    NOTE:

    2000 W PSUs: 25 A fuse

    2500 W PSUs: 50 A fuse

    3000 W PSUs: 25 A fuse

    800 W PSUs: 12.5 A fuse

    Rated power

    Two or four PSUs can be installed on one server.

    PSU rated power:

    Two PSUs:

    2500 W DC PSUs: 2500 W (input voltage: –48 V DC to –60 V DC)

    2000 W AC PSUs:

    800 W (input voltage: 100 V to 130 V AC)

    1800 W (input voltage: 200 V to 220 V AC)

    2000 W (input voltage: 220 V to 240 V AC)

    2000 W (input voltage: 240 V DC)

    3000 W AC PSUs:

    1200 W (input voltage: 100 V to 130 V AC)

    2500 W (input voltage: 200 V to 220 V AC)

    3000 W (input voltage: 220 V to 240 V AC)

    3000 W (input voltage: 240 V DC)

    Four PSUs:

    800 W AC PSUs:

    600 W (input voltage: 100 V to 127 V AC)

    800 W (input voltage: 200 V to 240 V AC)

    800 W (input voltage: 240 V DC)

    ]
  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
Huawei FusionServer RH5885H V3 Rack Server

Huawei FusionServer RH5885H V3 Rack Server...

Overview Specification Support Warranty

Overview Of Huawei FusionServer RH5885H V3 Rack Server

No Data Found

Specification Of Huawei FusionServer RH5885H V3 Rack Server

Huawei FusionServer RH5885H V3 Rack Server Datasheet

Huawei FusionServer RH5885H V3 Rack Server Specification

Huawei FusionServer RH5885H V3 Rack Server Specifications

Form factor/height

4U rack server, supporting hold rails and cable management assemblies.

Processor

A maximum of four Intel® Xeon® E7-4800 or E7-8800 v2 (Ivy Bridge-EX) processors, with up to 15 cores and 37.5 MB L3 cache per processor.

A maximum of four Intel® Xeon® E7-4800 or E7-8800 v3 (Haswell-EX) processors, with up to 18 cores and 45 MB L3 cache per processor.

A maximum of four Intel® Xeon® E7-4800 or E7-8800 v4 (Broadwell-EX) processors, with up to 24 cores and 60 MB L3 cache per processor.

Chipset

Intel Patsburg PCH.

DIMM slot

96 slots for installing DDR3 or DDR4 DIMMs.

There are 8 memory risers in total. Each processor supports two memory risers, and each memory riser supports 8 or 12 DIMMs.

Maximum memory capacity

6 TB (using 64 GB DIMMs).

Hard disk tray

8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.

23 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs.

8 x 2.5-inch hot-swappable SAS HDDs, SATA HDDs, or SSDs + 4 x 2.5-inch scheduled hot-swappable NVMe PCIe SSDs.

NOTICE:

The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSDs and Intel NVMe PCIe SSDs at the same time.

When Huawei ES3000 V3 NVMe PCIe SSDs are installed, upgrade the ES3000 V3 driver to the latest version.

Maximum local storage capacity

8 hard disks: 8 x 1.2 TB = 9.6 TB

23 hard disks: 23 x 1.2 TB = 27.6 TB

8 + 4 hard disks: 8 x 1.2 TB + 4 x 2 TB = 17.6 TB

NOTE:

The RH5885H V3 supports 8, 23, and 8 + 4 hard disk configurations.

RAID

A RAID controller card supports either of the following:

RAID 0, 1, 10, and 1E

RAID 0, 1, 10, 5, 50, 6, and 60, a maximum cache capacity of 2 GB, and a supercapacitor for power-off protection

Network port

The onboard NIC can be flexibly configured to provide either of the following ports:

Four integrated GE 1000BASE-T ports

Two 10GE optical ports

Two GE electrical ports

Expansion slot

The RH5885H V3 supports a non-standard PCIe slot dedicated for a RAID controller card.

The RH5885H V3 also supports various PCIe risers with different PCIe specifications:

16 standard PCIe slots

Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

Eight PCIe 3.0 x8 slots for installing full-height full-length cards

Two PCIe 3.0 x4 slots for installing full-height full-length cards

Two PCIe 2.0 x4 slots for installing full-height full-length cards

12 standard PCIe slots

Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

Four PCIe 3.0 x16 slots for installing full-height full-length cards

Two PCIe 3.0 x4 slots for installing full-height full-length cards

Two PCIe 2.0 x4 slots for installing full-height full-length cards

14 standard PCIe slots

Four PCIe 3.0 x8 slots for installing full-height full-length cards, supporting hot swap without opening the chassis cover

Four PCIe 3.0 x8 slots for installing full-height full-length cards

Two PCIe 3.0 x16 slots for installing full-height full-length cards

Two PCIe 3.0 x4 slots for installing full-height full-length cards

Two PCIe 2.0 x4 slots for installing full-height full-length cards

NOTICE:

The RH5885H V3 cannot be equipped with Huawei ES3000 V3 NVMe PCIe SSD cards and Intel NVMe PCIe SSDs at the same time.

When Huawei ES3000 V3 NVMe PCIe SSD cards are installed, upgrade the ES3000 V3 driver to the latest version.

External port

Front panel: two USB 2.0 ports, one power button, one UID button, one video graphics array (VGA) port, and one touched diagnostic LCD.

Rear panel: two USB 2.0 ports, one VGA port, one serial port, one 100 Mbit/s management port, one UID indicator, and one plug-in NIC.

DVD-ROM drive

One

PSU

The PSUs can be configured as follows:

Two 3000 W AC PSUs in 1+1 redundancy mode

Two 2000 W AC PSUs in 1+1 redundancy mode

Two 2500 W DC PSUs in 1+1 redundancy mode

Four 800 W AC PSUs in 2+2 redundancy mode

System management

IPMI/SNMP/CLI

Security feature

Power-on password and administrator password.

Front bezel.

Video card

The system mainboard integrates the display chip and provides 16 MB display memory. The maximum resolution is 1024 x 768.

Technical Specifications

Chassis dimensions (H x W x D)

175 mm x 447 mm x 790 mm (6.89 in. x 17.60 in. x 31.10 in.)

Installation space

The server fits into a standard cabinet that complies with the IEC 297 standard:

Width: 19 in.

Minimum depth: 1000 mm (39.37 in.)

The guide rails to be used vary with cabinets:

Use L-shaped guide rails for a Huawei cabinet.

Use adjustable guide rails if the distance between the front and rear mounting bars of a cabinet is 560 mm (22.05 in.) to 858 mm (33.78 in.).

Use holding rails if the distance between the front and rear mounting bars of a cabinet is 610 mm (24.02 in.) to 914 mm (35.98 in.).

Maximum weight

8-bay server: 52 kg (114.66 lb)

12-bay server: 53 kg (116.84 lb)

23-bay server: 56 kg (123.48 lb)

NOTE:

Maximum weight

Includes the weight of CPUs, DIMMs, and hard disks in full configuration.

Does not include the weight of the package or PCIe cards.

PCIe card weight

Standard half-height half-length PCIe card: 0.3 kg (0.66 lb)

Standard full-height half-length PCIe card: 0.4 kg (0.88 lb)

Standard full-height full-length dual-slot PCIe card (for example, a GPU): 1 kg (2.21 lb)

Package: 7 kg (15.44 lb)

Temperature

Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Class A3 compliant)

Storage temperature: -40°C to +65°C (-40°F to +149°F)

Maximum temperature change rate: 20°C/h (36°F/h)

Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

NOTE:

If an SSD card or a GPU is configured, the maximum operating temperature is 35°C (95°F).

Relative humidity (non-condensing)

Operating humidity: 10% to 90%

Storage humidity: 5% to 95%

Maximum humidity change rate: 20%/h

Long-term storage humidity: 30% RH to 69% RH (non-condensing)

Altitude

≤ 3000 m (9842.40 ft)

The highest operating temperature decreases by 1°C (1.8°F) with every increase of 300 m (984.24 ft) in an altitude above 900 m (2952.72 ft).

At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used.

HDDs are not supported at an altitude of over 3000 m (9842.5 ft).

Acoustic noise

The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

Idle:

LWAd: 7.1 Bels

LpAm: 58.8 dBA

Operating:

LWAd: 7.1 Bels

LpAm: 58.8 dBA

NOTE:

The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

Corrosive air pollutant

Corrosion rate of the copper test piece: < 300 Ã…/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)

Corrosion rate of the silver test piece: < 200 Ã…/month

Particulate pollutant

The ISO14664-1 Class 8 requirements are met.

You are advised to ask a professional organization to monitor particulate pollutants in the equipment room.

There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

Input voltage

Two PSUs:

2500 W DC PSUs: –48 V DC to –60 V DC

2000 W AC PSUs:

100 V AC to 240 V AC, 50 Hz/60 Hz

240 V DC

3000 W AC PSUs:

100 V AC to 240 V AC, 50 Hz/60 Hz

240 V DC

Four PSUs:

800 W AC PSUs:

100 V AC to 240 V AC, 50 Hz/60 Hz

240 V DC

NOTE:

Recommended current for external circuit breakers:

DC: 63 A

AC: 32 A

380 V HVDC: 32 A

Input current

DC PSUs: 63 A

AC PSUs: 10 A or 16 A

HVDC PSUs: 10 A or 16 A

NOTE:

2000 W PSUs: 25 A fuse

2500 W PSUs: 50 A fuse

3000 W PSUs: 25 A fuse

800 W PSUs: 12.5 A fuse

Rated power

Two or four PSUs can be installed on one server.

PSU rated power:

Two PSUs:

2500 W DC PSUs: 2500 W (input voltage: –48 V DC to –60 V DC)

2000 W AC PSUs:

800 W (input voltage: 100 V to 130 V AC)

1800 W (input voltage: 200 V to 220 V AC)

2000 W (input voltage: 220 V to 240 V AC)

2000 W (input voltage: 240 V DC)

3000 W AC PSUs:

1200 W (input voltage: 100 V to 130 V AC)

2500 W (input voltage: 200 V to 220 V AC)

3000 W (input voltage: 220 V to 240 V AC)

3000 W (input voltage: 240 V DC)

Four PSUs:

800 W AC PSUs:

600 W (input voltage: 100 V to 127 V AC)

800 W (input voltage: 200 V to 240 V AC)

800 W (input voltage: 240 V DC)

]
Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies