Overview Of JH326A
No Data FoundSpecification Of JH326A
JH326A Datasheet
Specification | |
---|---|
Type | HPE 5130 48G PoE+ 4SFP+ HI with 1 Interface Slot Switch |
System specifications | |
I/O ports and slots | 48 RJ-45 autosensing 10/100/1000 POE+ ports (IEEE 802.3 Type 10BASE-T, IEEE 802.3u Type 100BASETX, IEEE 802.3ab Type 1000BASE-T); Media Type: Auto-MDIX; Duplex: 10BASE-T/100BASE-TX: half or full; 1000BASE-T: full only; Ports 1 - 8 support MACSec
4 SFP+ 10GbE ports 1 port expansion module slot Supports a maximum of 6 SFP+ ports or 2 1/10GBASE-T ports, with optional module |
Memory and processor | 2 GB SDRAM; Packet buffer size: 4 MB, 512 MB flash |
Mounting and enclosure | Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included) |
Fan tray | Airflow direction is Front (port side) to Back (power cord side) |
1000 Mb Latency | < 5 µs |
10 Gbps Latency | < 3 µs |
Throughput | up to 190.5 Mpp/s |
Routing/Switching capacity | 256 Gb/s |
Routing table size | 32768 entries (IPv4), 16384 entries (IPv6) |
MAC address table size | 32768 entries |
Power supplies | 2 power supply slots
1 minimum power supply required (ordered separately) |
Physical specifications | |
Dimensions (H x W x D) | 4.37 x 43.99 x 46 cm (1.72 x 17.32 x 18.11 in) (1U height) |
Weight | 12.5 kg (27.56 lb) |
Electrical specifications | |
Frequency | 50 / 60 Hz |
Maximum heat dissipation | 365 BTU/hr (385.08 kJ/hr), Ranges from 167 BTU/hr to 392 BTU/hr, depending on power supply configuration |
Voltage | 100 - 240 V ac, rated (90 - 264 Vac, max)
-48 to -60 V dc, rated (-36 to -72 V dc, max) (depending on power supply chosen) |
Idle power | 55 W |
Maximum power rating | 107 W |
PoE power | N/A |
Environmental specifications | |
Operating Temperature | 0°C to 55°C (32°F to 131°F); 40°C (32°F to 104°F) when used with any SFP+ 10-GbE |
Operating relative humidity | 40°C (15% to 95% @ 104°F) noncondensing |
Nonoperating/Storage temperature | -40°C to 70°C (-40°F to 158°F) |
Nonoperating/Storage relative humidity | 65°C (15% to 90% @ 149°F) noncondensing |
Acoustic | Pressure: 51.8 dB, Low-speed fan: 51.8 dB, High-speed fan: 55.3 dB; ISO 7779 |
Safety agency certifications and emissions | |
Safety | UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR Subchapter J; NOM; ROHS Compliance |
Emissions | EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A; EN 61000-4-11:2004; ANSI C63.4-2009; EN 61000-3-3:2008; VCCI V-4/2012.04; EN 6100-3-2:2006+A1:2009 + A2:2009; EN 61000-3- 2:2006+A1:2009+A2:2009 ; EN 61000-4-3:2006; EN 61000-4-4:2012; EN 61000-4-5:2006; EN 61000- 4-6:2009; AS/NZS CISPR 22:2009 Class A; CISPR 22:2008 Class A; EN 55022:2010 Class A; EN 61000- 4-29: 2000; CISPR 24:2010; EN 300 386 V1.6.1; VCCI V-3/2013.04 Class A |
Immunity | Generic EN 55024
ESD EN300 386 |
Management | IMC - Intelligent Management Center, Command-line interface, Web browser, SNMP manager |