Overview Of S5300-28X-LI-24S-AC
No Data FoundSpecification Of S5300-28X-LI-24S-AC
S5300-28X-LI-24S-AC Datasheet
S5300-28X-LI-24S-AC Specification
S5300-28X-LI-24S-AC Specification |
|
Memory (RAM) |
256 MB |
Mean time between failures (MTBF) |
89.91 years |
Mean time to repair (MTTR) |
2 hours |
Availability |
> 0.99999 |
Service port surge protection |
Combo electrical ports on the CSFP switch: ±2 kV in common mode; electrical ports on the other models: ±6 kV in common mode |
Power supply surge protection |
AC: ±6 kV in differential mode; ±6 kV in common mode |
Dimensions (W x D x H) |
442.0 mm x 220.0 mm x 43.6 mm |
Weight |
‰¤ 5 kg |
RPS |
Yes |
PoE |
Not supported |
Rated voltage range |
100 V AC to 240 V AC, 50/60 Hz |
Maximum voltage range |
90 V AC to 264 V AC, 47 Hz to 63 Hz |
Maximum system power consumption (100% throughput, full speed of fans) |
60 W
|
Operating temperature |
0°C to 45°C at an altitude between 0 m and 1800 m NOTE When the altitude is between 1800 m and 5000 m, the highest operating temperature reduces 1°C every time the altitude increases 220 m. |
Storage temperature |
-40°C to +70°C |
Noise under normal temperature (27°C, sound power) |
less than 49.6 dBA
|
Relative humidity |
5% RH to 95% RH, noncondensing |
Operating altitude |
0 m to 5000 m |
EMC |
CISPR22 Class A CISPR24 EN55022 Class A EN50024 ETSI EN 300 386 Class A CFR 47 FCC Part 15 Class A ICES 003 Class A AS/NZS CISPR22 Class A IEC61000-4-2 ITU-T K 20 ITU-T K 44 |
Environmental standards |
RoHS REACH WEEE |
Safety |
IEC 60950-1 EN 60950-1/A11/A12 UL 60950-1 CSA C22.2 No 60950-1 AS/NZS 60950.1 |
Laser Safety |
IEC60825-1 IEC60825-2 EN60825-1 EN60825-2 |