huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • S5735S-S24T4S-A

    Huawei S5735-S switch, 24 × 10/100/1000Base-T ports, 4 × GE SFP ports, 1 × 60W AC Power Supply, Distribution model
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • S5735S-S24T4S-A Specification

    S5735S-S24T4S-A Specification

    Memory (RAM)

    1 GB

    Flash

    512 MB in total. To view the available flash memory size, run the display version command.

    Mean time between failures (MTBF)

    69.42 years

    Mean time to repair (MTTR)

    1.73 hours

    Availability

    > 0.99999

    Service port surge protection

    Common mode: ±7 kV

    Power supply surge protection

    Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode

    Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode

    Dimensions (H x W x D)

    Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)

    Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)

    Stack ports

    Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)

    RTC

    Supported

    RPS

    Not supported

    PoE

    Not supported

    Rated voltage range

    AC input: 100 V AC to 240 V AC, 50/60 Hz

    High-Voltage DC input: 240 V DC

    DC input: -48 V DC to -60 V DC

    Maximum voltage range

    AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz

    High-Voltage DC input: 190 V DC to 290 V DC

    DC input: -38.4 V DC to -72 V DC

    Maximum power consumption (100% throughput, full speed of fans)

    44 W

    Typical power consumption (30% of traffic load)

    Tested according to ATIS standard

    EEE enabled

    No PoE power consumption

    29 W

    Operating temperature

    -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)

    NOTE:

    When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

    The switch cannot be started when the ambient temperature is lower than 0°C (32°F).

    Short-term operating temperature

    -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)

    NOTE:

    When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

    The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

    The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.

    The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.

    The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.

    The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

    The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

    Storage temperature

    -40°C to +70°C (-40°F to +158°F)

    Noise under normal temperature (27°C, sound power)

    < 58.9 dB(A)

    Relative humidity

    5% to 95%, noncondensing

    Operating altitude

    0-5000 m (0-16404 ft.)

    Certification

    EMC certification

    Safety certification

    Manufacturing certification

  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
S5735S-S24T4S-A

Huawei S5735-S switch, 24 × 10/100/100...

Overview Specification Support Warranty

Overview Of S5735S-S24T4S-A

No Data Found

Specification Of S5735S-S24T4S-A

S5735S-S24T4S-A Datasheet

S5735S-S24T4S-A Specification

S5735S-S24T4S-A Specification

Memory (RAM)

1 GB

Flash

512 MB in total. To view the available flash memory size, run the display version command.

Mean time between failures (MTBF)

69.42 years

Mean time to repair (MTTR)

1.73 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±7 kV

Power supply surge protection

Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode

Using DC power modules: ±2 kV in differential mode, ±4 kV in common mode

Dimensions (H x W x D)

Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.4 in. x 16.5 in.)

Maximum dimensions (the depth is the distance from ports on the front panel to the handle on the rear panel): 43.6 mm x 442.0 mm x 444.2 mm (1.72 in. x 17.4 in. x 17.49 in.)

Stack ports

Any 10/100/1000BASE-T ports or 1000BASE-X ports (applicable in V200R019C10 and later versions)

RTC

Supported

RPS

Not supported

PoE

Not supported

Rated voltage range

AC input: 100 V AC to 240 V AC, 50/60 Hz

High-Voltage DC input: 240 V DC

DC input: -48 V DC to -60 V DC

Maximum voltage range

AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz

High-Voltage DC input: 190 V DC to 290 V DC

DC input: -38.4 V DC to -72 V DC

Maximum power consumption (100% throughput, full speed of fans)

44 W

Typical power consumption (30% of traffic load)

Tested according to ATIS standard

EEE enabled

No PoE power consumption

29 W

Operating temperature

-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)

NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The switch cannot be started when the ambient temperature is lower than 0°C (32°F).

Short-term operating temperature

-5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.)

NOTE:

When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met:

The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year.

The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year.

The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year.

The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded.

The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 58.9 dB(A)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-5000 m (0-16404 ft.)

Certification

EMC certification

Safety certification

Manufacturing certification

Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies