huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • S6720S-26Q-EI-24S-DC

    S6720S-26Q-EI-24S Bundle(24 10 Gig SFP+,2 40 Gig QSFP+,with 170W DC power supply)
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • S6720S-26Q-EI-24S-DC Specification

    S6720S-26Q-EI-24S-DC Specifications

    Fixed Ports

    24 x 10 GE SFP+, 2 x 40 GE QSFP+ ports

    Extended Slot

    Not supported

    MAC Address Table

    288K  MAC address entries 
    MAC address learning and aging 
    Static, dynamic, and black hole MAC address entries 
    Packet filtering based on source MAC addresses

    VLAN

    4K VLANs
    Guest VLAN and voice VLAN
    VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
    1:1 and N:1 VLAN Mapping
    QinQ and selective QinQ

    IPv4 Routing

    Static routing, RIPv1, RIPv2, ECMP, and URPF
    OSPF, IS-IS, and BGP
    VRRP
    Policy-based routing
    Routing policy

    IPv6 Routing

    Static route   
    RIPng   
    OSPFv3
    BGP4+
    ISISv6

    IPv6 Features

    Neighbor Discovery (ND) 
    PMTU
    IPv6 ping, IPv6 tracert, and IPv6 Telnet  
    6to4 tunnel, ISATAP tunnel, and manually configured tunnel
    ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type
    MLD v1/v2 snooping

    Multicast

    Static Layer 2 multicast MAC address 
    MAC-based multicast forwarding 
    IGMP snooping and IGMP fast leave    
    Multicast VLAN 
    MLD snooping   
    IGMP proxy
    Controllable multicast
    Port-based multicast traffic statistics
    IGMP v1/v2/v3 
    PIM-SM, PIM-DM, and PIM-SSM  
    MSDP
    MVPN

    QoS/ACL

    Rate limiting on packets sent and received by an interface
    Packet redirection
    Port-based traffic policing and two-rate three-color CAR
    Eight queues on each port
    WRR, DRR, SP, WRR + SP, and DRR + SP queue scheduling algorithms
    Re-marking of the 802.1p priority and DSCP priority
    Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN ID
    Rate limiting in each queue and traffic shaping on ports

    MPLS

    MPLS, MPLS VLL, L3VPN

    VPLS

    Martini VPLS

    Reliability

    STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
    BPDU protection, root protection, and loop protection   
    RRPP ring topology and RRPP multi-instance 
    Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover 
    SEP  
    ERPS (G.8032v2) 
    BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM
    E-Trunk

    Security

    User privilege management and password protection             
    DoS attack defense, ARP attack defense, and ICMP attack defense     
    Binding of the IP address, MAC address, interface, and VLAN 
    Port isolation, port security, and sticky MAC     
    Blackhole MAC address entries 
    Limit on the number of learned MAC addresses 
    802.1x authentication and limit on the number of users on an interface 
    AAA authentication, RADIUS authentication and TACACS authentication 
    SSH v2.0  
    Hypertext Transfer Protocol Secure (HTTPS) 
    CPU defense
    Blacklist and whitelist

    Super Virtual Fabric (SVF)

    Working as the parent node to vertically virtualize downlink switches as one device for management, supports two-layer clients architecture
    Support as a client node to be managed by SVF parent

    Management and Maintenance

    iStack (using service ports as stack ports)             
    MAC Forced Forwarding (MFF)             
    Virtual cable test             
    Ethernet OAM (IEEE 802.3ah and 802.1ag)             
    Local port mirroring and Remote Switched Port Analyzer (RSPAN), allowing an observing port to forward packets             
    Remote configuration and maintenance using Telnet             
    SNMP v1/v2c/v3             
    RMON             
    Web NMS             
    System logs and alarms of different levels             
    GVRP             
    MUX VLAN

    Operating Environment

    Operating temperature: 0m to 1,800m: 0°C to 45°C; 1,800m to 5,000m: 1°C decrease for every 220m increase in altitude
    Relative humidity: 5% to 95% (non-condensing)

    Input Voltage

    DC:                         
    Rated voltage range: €“48V to €“60V                         
    Maximum voltage range: €“36V to €“72V

    Dimensions (W x D x H)

    442 mm x 220 mm x 44.4 mm

    Typical  Power Consumption

    DC:
    without subcard: 101W

  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
S6720S-26Q-EI-24S-DC

S6720S-26Q-EI-24S Bundle(24 10 Gig SFP+,2 ...

Overview Specification Support Warranty

Overview Of S6720S-26Q-EI-24S-DC

No Data Found

Specification Of S6720S-26Q-EI-24S-DC

S6720S-26Q-EI-24S-DC Datasheet

S6720S-26Q-EI-24S-DC Specification

S6720S-26Q-EI-24S-DC Specifications

Fixed Ports

24 x 10 GE SFP+, 2 x 40 GE QSFP+ ports

Extended Slot

Not supported

MAC Address Table

288K  MAC address entries 
MAC address learning and aging 
Static, dynamic, and black hole MAC address entries 
Packet filtering based on source MAC addresses

VLAN

4K VLANs
Guest VLAN and voice VLAN
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports
1:1 and N:1 VLAN Mapping
QinQ and selective QinQ

IPv4 Routing

Static routing, RIPv1, RIPv2, ECMP, and URPF
OSPF, IS-IS, and BGP
VRRP
Policy-based routing
Routing policy

IPv6 Routing

Static route   
RIPng   
OSPFv3
BGP4+
ISISv6

IPv6 Features

Neighbor Discovery (ND) 
PMTU
IPv6 ping, IPv6 tracert, and IPv6 Telnet  
6to4 tunnel, ISATAP tunnel, and manually configured tunnel
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type
MLD v1/v2 snooping

Multicast

Static Layer 2 multicast MAC address 
MAC-based multicast forwarding 
IGMP snooping and IGMP fast leave    
Multicast VLAN 
MLD snooping   
IGMP proxy
Controllable multicast
Port-based multicast traffic statistics
IGMP v1/v2/v3 
PIM-SM, PIM-DM, and PIM-SSM  
MSDP
MVPN

QoS/ACL

Rate limiting on packets sent and received by an interface
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues on each port
WRR, DRR, SP, WRR + SP, and DRR + SP queue scheduling algorithms
Re-marking of the 802.1p priority and DSCP priority
Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN ID
Rate limiting in each queue and traffic shaping on ports

MPLS

MPLS, MPLS VLL, L3VPN

VPLS

Martini VPLS

Reliability

STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)
BPDU protection, root protection, and loop protection   
RRPP ring topology and RRPP multi-instance 
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover 
SEP  
ERPS (G.8032v2) 
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM
E-Trunk

Security

User privilege management and password protection             
DoS attack defense, ARP attack defense, and ICMP attack defense     
Binding of the IP address, MAC address, interface, and VLAN 
Port isolation, port security, and sticky MAC     
Blackhole MAC address entries 
Limit on the number of learned MAC addresses 
802.1x authentication and limit on the number of users on an interface 
AAA authentication, RADIUS authentication and TACACS authentication 
SSH v2.0  
Hypertext Transfer Protocol Secure (HTTPS) 
CPU defense
Blacklist and whitelist

Super Virtual Fabric (SVF)

Working as the parent node to vertically virtualize downlink switches as one device for management, supports two-layer clients architecture
Support as a client node to be managed by SVF parent

Management and Maintenance

iStack (using service ports as stack ports)             
MAC Forced Forwarding (MFF)             
Virtual cable test             
Ethernet OAM (IEEE 802.3ah and 802.1ag)             
Local port mirroring and Remote Switched Port Analyzer (RSPAN), allowing an observing port to forward packets             
Remote configuration and maintenance using Telnet             
SNMP v1/v2c/v3             
RMON             
Web NMS             
System logs and alarms of different levels             
GVRP             
MUX VLAN

Operating Environment

Operating temperature: 0m to 1,800m: 0°C to 45°C; 1,800m to 5,000m: 1°C decrease for every 220m increase in altitude
Relative humidity: 5% to 95% (non-condensing)

Input Voltage

DC:                         
Rated voltage range: €“48V to €“60V                         
Maximum voltage range: €“36V to €“72V

Dimensions (W x D x H)

442 mm x 220 mm x 44.4 mm

Typical  Power Consumption

DC:
without subcard: 101W

Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies