Overview Of SSE-DCM(F)-C-TWRS(120km)
No Data FoundSpecification Of SSE-DCM(F)-C-TWRS(120km)
SSE-DCM(F)-C-TWRS(120km) Datasheet
Huawei OptiX OSN 6800 Specification
Huawei OptiX OSNÂ 6800Â Specification |
||
Dimensions (mm) |
497 (W) x 295 (D) x 400 (H) |
|
Number of slots for service boards |
17 |
|
Switch |
Optical |
1 to 20-degree ROADM |
Electrical |
• 180G GE • 360G 10GE/ODUk(k=1, 2, 2e) |
|
Wavelength (max) |
DWDM: 80-ch, CWDM: 8-ch |
|
Wavelength range  |
DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1) CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2) |
|
Max. rate per channel |
100 Gbit/s (OTU4) |
|
Service types supported |
SDH, SONET, Ethernet, SAN, OTN, Video |
|
Line rate |
2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s |
|
Supported pluggable optical modules |
eSFP, SFP+, XFP, CFP |
|
Max. capacity per PID group |
120 Gbit/s |
|
Topology  |
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, me |
|
Redundancy and protection |
Network level protection (OTN) Â Â |
Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, MS SNCP, ODUk SPRing protection, OWSP, board-Level protection |
Network level protection (Ethernet) |
DBPS, DLAG, ERPS, LAG, LPT, MSTP, STP and RSTP, VLAN SNCP |
|
Equipment level protection  |
Power redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy |
|
Optical power management |
ALS, AGC, ALC, APE, IPA, OPA |
|
Synchronization  |
• Synchronous Ethernet clock • IEEE 1588v2 • 2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source •External time source (1PPS+TOD) |
|
ASON |
Optical-Layer ASON |
|
Nominal working voltage |
-48 V DC/-60 V DC |
|
Maximum subrack power consumption |
1350 W |
|
Operation environment  |
Subrack temperature: • Long-term operation: 5°C (41 °F) to 45°C (113 °F) • Short-term operation: -5°C (23 °F) to 55°C (131 °F) Relative humidity: • Long-term operation: 5% to 85% • Short-term operation: 5% to 95% |
|
Mean time to repair (MTTR) |
4 hours |
|
Mean time between failures (MTBF) |
51.64 years |