Overview Of TN13VA101
No Data FoundSpecification Of TN13VA101
TN13VA101 Datasheet
Huawei OptiX OSN 3800 Specification
Huawei OptiX OSN 3800Â Specification |
||
Dimensions (mm) |
436 (W) x 295 (D) x 134 (H) |
|
Number of slots for service boards |
4 |
|
Wavelength (max) |
DWDM: 80-ch, CWDM: 8-ch |
|
Wavelength range  |
DWDM: 1529.16 nm to 1560.61 nm (Band-C, ITU-T G.694.1) CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2) |
|
Max. rate per channel |
100 Gbit/s (OTU4) |
|
Service types supported |
SDH, SONET, Ethernet, SAN, OTN, Video |
|
Line rate |
2.5 Gbit/s, 10 Gbit/s, 100 Gbit/s |
|
Supported pluggable optical modules |
eSFP, SFP+, XFP, CFP |
|
Topology |
Point-to-point, chain, ring |
|
Redundancy and protection |
Network level protection   |
Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, MS SNCP, OWSP, board-Level protection |
DBPS, DLAG, ERPS, LAG, LPT, MSTP, STP and RSTP, VLAN SNCP |
||
Equipment level protection |
Power redundancy, fan redundancy, system control and communication board redundancy |
|
Optical power management |
ALS, AGC, ALC, IPA |
|
Nominal working voltage |
-48 V DC/-60 V DC |
|
Maximum subrack power consumption  |
• AC power: 350 W • DC power: 420 W |
|
Operation environment  |
Subrack temperature: • Long-term operation: 5°C (41 °F) to 45°C (113 °F) • Short-term operation: -5°C (23 °F) to 55°C (131 °F) Relative humidity: • Long-term operation: 5% to 85% • Short-term operation: 5% to 95% |
|
Mean time to repair (MTTR) |
4 hours |
|
Mean time between failures (MTBF) |
27.35 years |