huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • TNVKFFRAME01

    Huawei OSN 9800 P32 subrack is an ultra-large capacity all-optical cross-connect product, used at the backbone core layer and metro aggregation layer and works with the OSN 9800/1800 to build a complete E2E WDM/OTN backbone transmission solution, achieving transparent and ultra-large capacity transmission
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • Huawei OptiX OSN 9800 P32 Specification

     Huawei OptiX OSN 9800 P32 Specifications

    Subrack dimensions (mm)

    1390 (H) x 496 (W) x 315 (D) (without cabinet)

    Suitable cabinet

    ETSI 300 cabinets, such as A63B

    Number of slots for service boards

    32

    Switching capability

    Optical

    1 to 32-degree reconfigurable optical add/drop multiplexer (ROADM)

    Electrical

    N/A

    Max. number of wavelengths

    Fixed grid: 96 wavelengths @50 GHz grid

    Flex grid: The maximum number of wavelengths is related to the width of the flex channel.

    Channel spacing

    Fixed grid: 50 GHz grid/100 GHz grid

    Flex grid: Supports channel spacing designs, and the minimum can be set to 6.25 GHz.

    Center wavelength range

    DWDM system: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.694.1)

    Topology

    Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh

    Redundancy and protection

    Network level protection

    Optical line protection

    Equipment level protection

    Power redundancy, fan redundancy, communication control and clock processing unit redundancy

    Optical power management

    IPA

    Easy O&M

    Optical Doctor System (OD), Fiber Doctor System (FD)

    Synchronization

    Synchronous Ethernet clock

    IEEE 1588v2

    ITU-T G.8275.1

    Power Supply

    Nominal working voltage:

    -48V DC/-60V DC

    Working voltage range:

    -48 V DC: -40 V to -57.6 V

    -60 V DC: -48 V to -72 V

    Operation environment

    Subrack temperature:

    Long-term operation: 5°C (41°F) to 40°C (104°F)

    Short-term operationba: -5°C (23°F) to 45°C (113°F)

    Relative humidity:

    Long-term operation: 5% to 85%

    Short-term operationa: 5% to 90%

    Mean Time To Repair (MTTR)

    4 hours

    Mean Time Between Failure (MTBF)

    64.37 years

    a: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days.

  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
TNVKFFRAME01

Huawei OSN 9800 P32 subrack is an ultra-la...

Overview Specification Support Warranty

Overview Of TNVKFFRAME01

No Data Found

Specification Of TNVKFFRAME01

TNVKFFRAME01 Datasheet

Huawei OptiX OSN 9800 P32 Specification

 Huawei OptiX OSN 9800 P32 Specifications

Subrack dimensions (mm)

1390 (H) x 496 (W) x 315 (D) (without cabinet)

Suitable cabinet

ETSI 300 cabinets, such as A63B

Number of slots for service boards

32

Switching capability

Optical

1 to 32-degree reconfigurable optical add/drop multiplexer (ROADM)

Electrical

N/A

Max. number of wavelengths

Fixed grid: 96 wavelengths @50 GHz grid

Flex grid: The maximum number of wavelengths is related to the width of the flex channel.

Channel spacing

Fixed grid: 50 GHz grid/100 GHz grid

Flex grid: Supports channel spacing designs, and the minimum can be set to 6.25 GHz.

Center wavelength range

DWDM system: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.694.1)

Topology

Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh

Redundancy and protection

Network level protection

Optical line protection

Equipment level protection

Power redundancy, fan redundancy, communication control and clock processing unit redundancy

Optical power management

IPA

Easy O&M

Optical Doctor System (OD), Fiber Doctor System (FD)

Synchronization

Synchronous Ethernet clock

IEEE 1588v2

ITU-T G.8275.1

Power Supply

Nominal working voltage:

-48V DC/-60V DC

Working voltage range:

-48 V DC: -40 V to -57.6 V

-60 V DC: -48 V to -72 V

Operation environment

Subrack temperature:

Long-term operation: 5°C (41°F) to 40°C (104°F)

Short-term operationba: -5°C (23°F) to 45°C (113°F)

Relative humidity:

Long-term operation: 5% to 85%

Short-term operationa: 5% to 90%

Mean Time To Repair (MTTR)

4 hours

Mean Time Between Failure (MTBF)

64.37 years

a: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days.

Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies