No Data FoundSpecification Of ST10000VX0004
ST10000VX0004 Datasheet
ST10000VX0004 Specification
ST10000VX0004Â Specification |
|
Formatted (512 bytes/sector) |
10TB |
Guaranteed sectors |
7,814,037,168 |
Heads |
14 |
Disks |
7 |
Bytes per logical sector |
512 |
Bytes per physical sector |
4096 |
Recording density, KBPI (Kb/in max) |
2230 |
Track density, KTPI (ktracks/in avg.) |
386 |
Areal density, (Gb/in2Â avg) |
867 |
Spindle speed (RPM) |
7200 |
Internal data transfer rate (Mb/s max) |
2695 |
Max sustained transfer rate, OD read (MB/s) |
210 |
I/O data-transfer rate (MB/s max) |
600 |
ATA data-transfer modes supported  |
PIO modes 0–4 Multiword DMA modes 0–2 Ultra DMA modes 0–6 |
Cache buffer |
256MB |
Average latency |
4.16ms |
Power-on to ready (sec) (typ/max) |
20/30 |
Standby to ready (sec) (typ/max) |
Standby to ready (sec) (typ/max) 20/30 |
Startup current (typical) 12V (peak) |
<=1.8A |
Voltage tolerance (including noise) |
5V ±5% 12V ±10% |
Non-Operating (Ambient ℃) |
–40℃ to 70℃ |
Operating ambient temperature (min ℃) |
5℃ |
Operating temperature (drive case max ℃) |
70℃ |
Temperature gradient (℃ per hour max) |
20℃ (operating) 30℃ (non-operating) |
Relative humidity |
5% to 95% (operating) 5% to 95% (non-operating) |
Relative humidity gradient |
30% per hour max |
Altitude, operating |
–304.8 m to 3,048 m(–1000 ft to 10,000+ ft) |
Altitude, non-operating(below mean sea level, max) |
–304.8 m to 12,192 m(–1000 ft to 40,000+ ft) |
Operational Shock (max at 2 ms) |
Read 70 Gs / Write 40 Gs |
Non-Operational Shock (max at 2 ms) |
250 Gs |
Vibration, operating  |
5–22 Hz: 0.25 Gs, Limited displacement 22–350 Hz: 0.50 Gs 350–500 Hz: 0.25 Gs |
Operation Rotational vibration |
20–1500Hz: 12.5 rads/s2 |
Vibration, non-operating |
2–500 Hz: 2.27 Grms ref |
Idle |
2.8 (typical) 3.0 (max) |
Performance seek |
3.2 (typical) 3.4 (max) |
Non-recoverable read errors |
1 sector per 1015Â bits read |
Annualized Failure Rate (AFR) |
0.88% based on 8760 POH |
Rated Workload  |
Average annualized workload rating: <180TB/year The AFR specification for the product assumes the I/O workload does not exceed the average annualized workload rate limit of 180 TB/year. Workloads exceeding the annualized rate may degrade the product AFR and impact reliability as experienced by the particular application. The average annualized workload rate limit is in units of TB per calendar year. |
Load-unload cycles |
300,000 Â |
Supports Hotplug operation per Serial ATA Revision 3.2 specification |
Yes |