huge-inventory.webp
free-shipping.webp
extended-replacement.webp
  • S5320-36C-EI-DC

    S5320-36C-EI-DC(28 Ethernet 10/100/1000 ports,4 of which are dual-purpose 10/100/1000 or SFP,4 10 Gig SFP+, 1 interface slot,with 150W DC)
  • Condition:

    New Factory Sealed
  • IN STOCK Delivery within 48 hours

  • Warranty:  3 Years *

  • S5320-36C-EI-DC Specification

    S5320-36C-EI-DC specification

    Item

    Description

    Memory (RAM)

    2 GB

    Flash

    340 MB

    Mean time between failures (MTBF)

    80.05 years when no card is configured; 73.65 years when a 2-port 10GE SFP+ interface card is configured; 71.58 years when a 2-port 10GE RJ45 interface card is configured; 71.74 years when a stack card is configured

    Mean time to repair (MTTR)

    2 hours

    Availability

    > 0.99999

    Service port surge protection

    Common mode: ±6 kV

    Power supply surge protection

    Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode

    Using DC power modules: ±1 kV in differential mode, ±2 kV in common mode

    Dimensions (W x D x H)

    442.0 mm x 420.0 mm x 44.4 mm (17.4 in. x 16.5 in. x 1.74 in.)

    Weight

    Empty: ‰¤ 8 kg (17.64 lb)

    Fully loaded: ‰¤ 12 kg (26.46 lb)

    Stack ports

    Ports on the 2-port QSFP+ rear stack card

    RPS

    Not supported

    PoE

    Not supported

    Rated voltage range

    100 V AC to 240 V AC, 50/60 Hz

    -48 V DC to -60 V DC

    Maximum voltage range

    90 V AC to 264 V AC, 47 Hz to 63 Hz

    -36 V DC to -72 V DC

    Maximum power consumption (100% throughput, full speed of fans)

    75.8 W

    Operating temperature

    0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5096 ft.)

    NOTE:

    When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

    Storage temperature

    -40°C to +70°C (-40°F to +158°F)

    Noise under normal temperature (27°C, sound power)

    < 51.2 dBA

    Relative humidity

    5% to 95%, noncondensing

    Operating altitude

    AC power modules configured: 0-5000 m (0-16404 ft.)

    DC power modules configured: 0-2000 m (0-6562 ft.)

    Certification

    EMC certification

    Safety certification

    Manufacturing certification

  • View full specification...

  • 3 Years Extended Warranty 100% Ready Stock Best Price Match
    100% Genuine Products 24/7 Technical Support
S5320-36C-EI-DC

S5320-36C-EI-DC(28 Ethernet 10/100/1000 po...

Overview Specification Support Warranty

Overview Of S5320-36C-EI-DC

No Data Found

Specification Of S5320-36C-EI-DC

S5320-36C-EI-DC Datasheet

S5320-36C-EI-DC Specification

S5320-36C-EI-DC specification

Item

Description

Memory (RAM)

2 GB

Flash

340 MB

Mean time between failures (MTBF)

80.05 years when no card is configured; 73.65 years when a 2-port 10GE SFP+ interface card is configured; 71.58 years when a 2-port 10GE RJ45 interface card is configured; 71.74 years when a stack card is configured

Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

Common mode: ±6 kV

Power supply surge protection

Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode

Using DC power modules: ±1 kV in differential mode, ±2 kV in common mode

Dimensions (W x D x H)

442.0 mm x 420.0 mm x 44.4 mm (17.4 in. x 16.5 in. x 1.74 in.)

Weight

Empty: ‰¤ 8 kg (17.64 lb)

Fully loaded: ‰¤ 12 kg (26.46 lb)

Stack ports

Ports on the 2-port QSFP+ rear stack card

RPS

Not supported

PoE

Not supported

Rated voltage range

100 V AC to 240 V AC, 50/60 Hz

-48 V DC to -60 V DC

Maximum voltage range

90 V AC to 264 V AC, 47 Hz to 63 Hz

-36 V DC to -72 V DC

Maximum power consumption (100% throughput, full speed of fans)

75.8 W

Operating temperature

0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5096 ft.)

NOTE:

When the altitude is 1800-5000 m (5096-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage temperature

-40°C to +70°C (-40°F to +158°F)

Noise under normal temperature (27°C, sound power)

< 51.2 dBA

Relative humidity

5% to 95%, noncondensing

Operating altitude

AC power modules configured: 0-5000 m (0-16404 ft.)

DC power modules configured: 0-2000 m (0-6562 ft.)

Certification

EMC certification

Safety certification

Manufacturing certification

Our Trusted Clientele Worldwide
Esr-Connect
Johnson-and-Johnson
Exon
Novartis
Siemens-Healthineers
Sheraton
Sk-Telecom
ASDA
DHL
UPS
Lezzat-ltd
Electrotechnical-certification-scheme
WHY ORM SYSTEMS
why orm system image
why orm system image
Technical Support

ORM Systems offers reliable and scalable renowned products that allow seamless expansion to performance and adaptability to network enterprises. Our professional team of highly skilled engineers provides 360 technical support to help you with presale and after-sales journeys to enable customers with features and capabilities of the products.

We strive to deliver a seamless experience that guarantees complete satisfaction along with guidance and support in service settings to promptly resolve issues.

Standard Services
Standard Services image
Standard Services image
Get Quote
Get a free quote!
× Thank you! your form has been submitted successfully. Our expert will be in touch with you shortly.
×
ORM Registered Companies