Name:
AP7564
- Description:
- AP7564 PDU BASIC 120/208V 5.7KW 0U RM 36XC13 6XC19
- Rating:
-
(0)
Added to cart 47 times recently
- Availability:
-
In stock - Ready to Ship
- Brand:
- Apc
- Condition:
- Warranty:
-
3 - List Price:
-
- Price:
-
Quantity:
1
3 Year Extended Warranty
Same-day Shipping
14-Day Money Back Guarantee
Need Additional Discount on Product?
Request a quote below - Get Exclusive Pricing and Support.
Exclusive Bulk Discounts tailored to your order size
Priority Processing with a dedicated account manager
Fast Response: Get your custom quote within 5-10 minutes during business hours (Mon-Fri, 6:00 AM – 6:00 PM PST)
Holiday Bonus: Submissions on holidays receive priority handling the next business day
Shipping:
Payment:
Shipping as per your need
Same-day Shipping
Express Delivery Across the USA
Need it fast? Choose Express Shipping and receive your order within 1–3 business days.
Free Ground Shipping Available
Standard ground delivery across the U.S. takes 2–6 days, depending on your location — no extra charge.
International Shipments Made Simple
For all international orders, we ship via your UPS, FedEx, or DHL account — or to your U.S.-based freight forwarder.
Delivery Timelines
Under 100 KG? Ships Express.
Smaller shipments go via DHL or FedEx Express — delivered worldwide in approximately 3 business days.
Over 100 KG? Ships via Freight.
Larger orders are dispatched through freight forwarding partners. Delivery takes 7–10 business days, globally.
Always Delivered to Your Door
Every shipment is delivered directly to your address — regardless of country or carrier.
14-Day Money Back Guarantee
Free 14-Day Returns
Tested it, but it’s not a fit?
Return any product within 14 days of delivery if it doesn’t meet your technical or operational needs.
Initiate returns with ease.
Our RMA process is streamlined — just raise a request, follow the packaging guidelines, and we’ll handle the rest.
Refund or restock, your call.
Changed your mind? Get a refund (restocking fees may apply) or swap with another product.
30-Day Hardware Replacement
Covered for any early faults.
All equipment includes a 30-day replacement warranty. If something goes wrong, we’ll repair or swap it — fast.
Replacements shipped in 10 days or less.
Once your return is inspected and approved, we dispatch the replacement promptly to keep your operations moving.
RMA protocol keeps it smooth.
Just ensure all accessories and original packaging are intact — we’ll take care of the technical validation.
TRUSTED, TRIED, PROVEN
AP7564 Overview
AP7564 is an enclosed cabinet rack designed to provide a robust 42U solution with a standard 19-inch mounting system and an overall depth of up to 600mm. It features a vented door for optimal airflow, integrated cable management, and supports passive ventilation, making it ideal for network closets, data centers, telecom racks, and AV equipment installations.
AP7564 offers reliable floor-standing performance with optional casters and included leveling feet, along with a front door locking mechanism to secure equipment. Its construction in steel, fixed side panels, and expansion-ready design ensure that it meets the high-demand requirements of professional IT environments.
What is the price of AP7564?
Pricing for AP7564 is available on request. Get immediate quote or for exclusive discounts, opt for bulk quotation for AP7564.
Explore more options from Racks or explore other Apc products.
AP7564 Specifications
| Product Type | Rack |
| Rack Type | Enclosed Cabinet |
| Mounting Type | Floor Standing |
| Rack Height (U) | 42U |
| Use Case | Data Center / Networking Closet / Telecom / AV Rack |
| Rack Width | 19-inch |
| Rack Depth | Up to 600mm |
| Weight Capacity | 501–1000 lbs |
| Material | Steel |
| Door Type | Vented Door |
| Side Panels | Fixed |
| Cable Management | Included |
| Cooling Support | Passive Ventilation |
| Locking Mechanism | Front Door Lock |
| Casters | Optional |
| Leveling Feet | Included |
| Rails Included | Yes |
| Expansion Ready | Yes |
| Grounding Kit Included | Yes |
| Color | Black |
| Compliance | RoHS |
| Product Name | AP7564 Enclosed Cabinet Rack |
| Height | 80 inches |
| Width | 24 inches |
| Depth | 30 inches |
| Weight | 350 lbs |
Quality Certifications
To get the detailed certification, please go to the Compliance Center.
Product Comparison Table
|
|
|
|
|
|
|
|---|---|---|---|---|---|
| Cable Management | Included | Included | Tool-less | Included | Included |
| Casters | Included | Included | Optional | No | Optional |
| Color | Black | Black | Black | Black | Black |
| Compliance | UL Listed | EIA-310-D / RoHS / UL Listed / CE | RoHS | RoHS / UL Listed / CE | RoHS |
| Cooling Support | Passive Ventilation | Passive Ventilation | Passive Ventilation | Passive Ventilation | Passive Ventilation |
| Depth | 36 inches | 36.2 inches | 39 inches | 30 inches | 30 inches |
| Door Type | Vented Door | Solid Door | Vented Door | Vented Door | Vented Door |
| Expansion Ready | Yes | Yes | Yes | Yes | Yes |
| Grounding Kit Included | Yes | Yes | Yes | Yes | Yes |
| Height | 76 inches | 73.5 inches | 78 inches | 78 inches | 80 inches |
| Leveling Feet | Included | Included | Included | Included | Included |
| Locking Mechanism | Rear Door Lock | Front Door Lock | Front Door Lock | Front Door Lock | Front Door Lock |
| Material | Cold-Rolled Steel | Cold-Rolled Steel | Cold-Rolled Steel | Cold-Rolled Steel | Steel |
| Mounting Type | Floor Standing | Floor Standing | Floor Standing | Floor Standing | Floor Standing |
| Product Name | AR100 Enclosed Server Rack | AR4000MVX429 Enclosed Data Center Rack | AR7589 Enclosed Cabinet Rack | AR8606 Enclosed Server Cabinet | AP7564 Enclosed Cabinet Rack |
| Product Type | Rack | Rack | Rack | Rack | Rack |
| Rack Depth | 800–1000mm | 1000mm+ | 800–1000mm | 600–800mm | Up to 600mm |
| Rack Height (U) | 42U | 42U | 42U | 42U | 42U |
| Rack Type | Enclosed Cabinet | Enclosed Cabinet | Enclosed Cabinet | Enclosed Cabinet | Enclosed Cabinet |
| Rack Width | 19-inch | 19-inch | 19-inch | 19-inch | 19-inch |
| Rails Included | Yes | Yes | Yes | Yes | Yes |
| Side Panels | Removable | Removable | Removable | Tool-less | Fixed |
| Use Case | Networking Closet / Data Center / AV Rack / Telecom | Data Center / Networking Closet / Telecom / AV Rack | Data Center / Networking Closet / Telecom / AV Rack | Data Center / Networking Closet / AV Rack / Telecom | Data Center / Networking Closet / Telecom / AV Rack |
| Weight | 150 lbs | 310 lbs | 280 lbs | 200 lbs | 350 lbs |
| Weight Capacity | 2000+ lbs | 2000+ lbs | 1001–2000 lbs | 501–1000 lbs | 501–1000 lbs |
| Width | 24 inches | 24.4 inches | 24 inches | 26 inches | 24 inches |
Showing - of 0 Results
Questions & Answers
Q
What is the APC AP7564 PDU Basic 120/208V 5.7kW 0U RM with 36×C13 and 6×C19?
A
The APC AP7564 is a zero-U, rack-mount power distribution unit delivering 120/208V, 5.7 kW capacity, with 36 C13 outlets and 6 C19 outlets for reliable server power management.
Q
Which equipment is compatible with the AP7564 PDU Basic?
A
The AP7564 is compatible with standard 19″ racks and supports IT equipment requiring C13 or C19 receptacles at 120/208 V power input, such as servers, switches, and storage arrays.
Q
What are the electrical specifications of the AP7564?
A
The AP7564 operates at 120/208 V AC, supports a maximum load of 5.7 kW, draws up to 27.5 A per phase, and is equipped with a 30 A input breaker for overcurrent protection.
Q
How do I install the zero-U rack-mount design?
A
Mount the AP7564 vertically alongside the rack frame rails using included brackets; no additional rack units are consumed, preserving valuable space for IT equipment.
Q
Does the AP7564 include surge protection?
A
The AP7564 Basic model does not include surge suppression; for surge protection, consider the metered or metered-by-outlet models in the same series.
Q
How many outlets does the AP7564 provide?
A
The unit offers 42 outlets in total: 36 C13 outlets for low-current devices and 6 C19 outlets for high-current equipment.
Q
Can I monitor power usage on the AP7564?
A
The AP7564 Basic model does not feature remote monitoring; for real-time amperage and kWh data, choose the metered or monitored variant.
Q
What safety certifications does the AP7564 have?
A
The AP7564 is UL 60950-1 and CE certified, ensuring compliance with North American and European electrical safety standards.
Q
What is the warranty period for the AP7564?
A
APC provides a two-year limited warranty covering defects in materials and workmanship under normal use conditions.
Q
What are the dimensions and weight of the AP7564?
A
The AP7564 measures 1.2 × 17.5 × 3.9 inches (H × W × D) and weighs approximately 5.3 lbs, making it compact and lightweight for vertical rack mounting.
Q
How do I order replacement power cords for the AP7564?
A
Replacement input cords with matching NEMA or IEC configurations are available via APC part numbers; consult the APC accessory catalog or your authorized reseller.
Q
Is the AP7564 suitable for high-density data centers?
A
Yes, its zero-U design and high outlet count make the AP7564 ideal for high-density environments where rack space and reliable power distribution are critical.
Q
How do I balance loads across the AP7564 phases?
A
Distribute equipment evenly across the three input phases when connecting C13 and C19 outlets to maintain phase balance and minimize circuit imbalance.
Q
What ambient conditions does the AP7564 support?
A
The AP7564 operates reliably in ambient temperatures from 32 °F to 104 °F (0 °C to 40 °C) with a maximum relative humidity of 95% non-condensing.
Q
Can I cascade multiple AP7564 units in a single rack?
A
Yes, you can cascade PDUs by connecting the output of one AP7564 to the input of another, provided total load does not exceed rack circuit capacity.
Q
Where can I find technical support for the AP7564?
A
Technical support is available through APC by Schneider Electric’s online portal, telephone helpdesk, or authorized service partners for installation and troubleshooting.