D9N63A
- Description:
- HPE Metered 3Ph 19.9kVA/L22-30P 24A/277V Outlets (30) RF-203P-HP/Vertical NA PDU
- Rating:
-
(0)
Added to cart 15 times recently
- Availability:
-
In stock - Ready to Ship
- Brand:
- Hpe
- Condition:
- Warranty:
-
3 - List Price:
-
- Price:
-
Quantity:
1
3 Year Extended Warranty
Same-day Shipping
14-Day Money Back Guarantee
Need Additional Discount on Product?
Request a quote below - Get Exclusive Pricing and Support.
Exclusive Bulk Discounts tailored to your order size
Priority Processing with a dedicated account manager
Fast Response: Get your custom quote within 5-10 minutes during business hours (Mon-Fri, 6:00 AM – 6:00 PM PST)
Holiday Bonus: Submissions on holidays receive priority handling the next business day
Shipping:
Payment:
Shipping as per your need
Same-day Shipping
Express Delivery Across the USA
Need it fast? Choose Express Shipping and receive your order within 1–3 business days.
Free Ground Shipping Available
Standard ground delivery across the U.S. takes 2–6 days, depending on your location — no extra charge.
International Shipments Made Simple
For all international orders, we ship via your UPS, FedEx, or DHL account — or to your U.S.-based freight forwarder.
Delivery Timelines
Under 100 KG? Ships Express.
Smaller shipments go via DHL or FedEx Express — delivered worldwide in approximately 3 business days.
Over 100 KG? Ships via Freight.
Larger orders are dispatched through freight forwarding partners. Delivery takes 7–10 business days, globally.
Always Delivered to Your Door
Every shipment is delivered directly to your address — regardless of country or carrier.
14-Day Money Back Guarantee
Free 14-Day Returns
Tested it, but it’s not a fit?
Return any product within 14 days of delivery if it doesn’t meet your technical or operational needs.
Initiate returns with ease.
Our RMA process is streamlined — just raise a request, follow the packaging guidelines, and we’ll handle the rest.
Refund or restock, your call.
Changed your mind? Get a refund (restocking fees may apply) or swap with another product.
30-Day Hardware Replacement
Covered for any early faults.
All equipment includes a 30-day replacement warranty. If something goes wrong, we’ll repair or swap it — fast.
Replacements shipped in 10 days or less.
Once your return is inspected and approved, we dispatch the replacement promptly to keep your operations moving.
RMA protocol keeps it smooth.
Just ensure all accessories and original packaging are intact — we’ll take care of the technical validation.
TRUSTED, TRIED, PROVEN
D9N63A Overview
D9N63A is a high-performance power supply delivering 650W of continuous power through a fully modular design in a standard ATX form factor. It features an 80 PLUS Gold certification, operates over an input voltage range of 100–240V, and incorporates active PFC to optimize energy efficiency. The unit is cooled by a 120mm fan with a fluid dynamic bearing that ensures reliable performance and reduced noise levels even under heavy loads.
Built with robust quality, the D9N63A includes a comprehensive suite of safety protections – OCP, OVP, and SCP – to safeguard your components. It comes equipped with a wide array of connectors including one ATX 24-pin, one EPS (CPU) 4+4 pin, three PCIe (6+2) connectors for graphics cards, and six SATA power connectors. With an efficiency rating of 92% and premium sleeved cables, this power supply is well suited for high-demand use cases such as gaming, workstations, and even server applications.
What is the price of D9N63A?
Pricing for D9N63A is available on request. Get immediate quote or for exclusive discounts, opt for bulk quotation for D9N63A.
Explore more options from Power Distribution Units or explore other Hpe products.
D9N63A Specifications
| Product Type | Power Supply |
| Wattage | 650W |
| Use Case | Gaming / Workstation |
| Form Factor | ATX |
| Modularity | Modular |
| 80 PLUS Certification | Gold |
| Rail Configuration | Single Rail |
| Certifications | 80 PLUS / CE / FCC / UL / RoHS |
| Remote Monitoring | No |
| Input Voltage | 100–240V |
| Hot-Swap Capable | No |
| PFC (Power Factor Correction) | Active PFC |
| Fan Size | 120mm |
| Fan Bearing Type | Fluid Dynamic |
| Zero RPM Mode | Yes |
| Efficiency Rating | 92% |
| Protections | OCP / OVP / SCP |
| ATX 24-Pin Connectors | 1 |
| EPS (CPU) 4+4 Pin | 1 |
| PCIe (6+2) Connectors | 3 |
| SATA Power Connectors | 6 |
| Molex Connectors | 2 |
| Floppy Connector | No |
| Cable Type | Sleeved |
| RGB Lighting | No |
| MTBF (Mean Time Between Failures) | 150,000 hours |
| Operating Temperature | 50°C |
| Product Name | D9N63A 650W Modular ATX Power Supply |
| Height | 5.5 inches |
| Width | 8.6 inches |
| Depth | 6.3 inches |
| Weight | 4.5 lbs |
D9N63A Use Case
Real-Time Power Monitoring for Enterprise Data Centers
In large-scale enterprise data centers, IT operations teams deploy the D9N63A-HPE Metered 3Ph 19.9kVA/L22-30P 24A/277V Outlets (30) RF-203P-HP/Vertical NA PDU to capture phase-level power metrics across high-density racks. By feeding accurate kW, kVA and amperage readings into data center infrastructure management (DCIM) software, they proactively balance loads, prevent circuit overloads and plan capacity growth. Outcome: mitigates unplanned downtime, extends equipment lifespan and reduces operational costs through precise capacity planning.
SLA Compliance in Multi-Tenant Colocation Facilities
Colocation providers integrate the D9N63A-HPE Metered 3Ph 19.9kVA/L22-30P 24A/277V Outlets (30) RF-203P-HP/Vertical NA PDU to guarantee uninterrupted power delivery for customer racks. With 30 individually metered outlets and per-phase monitoring, technicians remotely track consumption and configure alert thresholds for each tenant. Outcome: ensures service-level agreement (SLA) compliance, enhances customer trust and simplifies billing by aligning actual usage data with invoicing.
Energy Efficiency Optimization in High-Performance Computing Clusters
Research labs and HPC centers leverage the D9N63A-HPE Metered 3Ph 19.9kVA/L22-30P 24A/277V Outlets (30) RF-203P-HP/Vertical NA PDU to manage power demands of GPU-accelerated racks under variable loads. Detailed per-outlet kW and kVA readings enable teams to detect phase imbalances, implement targeted power capping and redistribute workloads dynamically. Outcome: boosts energy efficiency by up to 15%, maximizes rack density and lowers total cost of ownership.
Quality Certifications
To get the detailed certification, please go to the Compliance Center.
Product Comparison Table
|
|
|
|
|
|
|
|---|---|---|---|---|---|
| 80 PLUS Certification | Gold | Gold | Gold | Gold | Gold |
| ATX 24-Pin Connectors | 1 | 1 | 1 | 1 | 1 |
| Cable Type | Sleeved | Sleeved | Sleeved | Sleeved | Braided |
| Certifications | 80 PLUS / CE / FCC / UL / RoHS | 80 PLUS, CE, FCC, UL, RoHS | 80 PLUS / CE / FCC / UL / RoHS | 80 PLUS / CE / FCC / UL / ROHS | 80 PLUS / CE / FCC / UL / RoHS |
| Depth | 6.3 inches | 5.9 inches | 5.51 inches | 5.5 inches | 6.3 inches |
| Efficiency Rating | 92% | 94% | 92% | 94% | 92% |
| EPS (CPU) 4+4 Pin | 1 | 1 | 1 | 1 | 2 |
| Fan Bearing Type | Fluid Dynamic | Fluid Dynamic | Fluid Dynamic | Fluid Dynamic | Fluid Dynamic |
| Fan Size | 120mm | 120mm | 120mm | 120mm | 140mm |
| Floppy Connector | No | No | No | No | No |
| Form Factor | ATX | ATX | ATX | ATX | ATX |
| Height | 5.5 inches | 3.4 inches | 3.39 inches | 5 inches | 5.5 inches |
| Hot-Swap Capable | No | No | No | No | No |
| Input Voltage | 100–240V | 100–240V | 100–240V | 100–240V | 100–240V |
| Modularity | Modular | Modular | Semi-Modular | Modular | Modular |
| Molex Connectors | 2 | 3 | 2 | 2 | 4 |
| MTBF (Mean Time Between Failures) | 150,000 hours | 150,000 hours | 100,000 hours | 150,000 hours | 150,000 hours |
| Operating Temperature | 50°C | 50°C | 50°C | 50°C | 50°C |
| PCIe (6+2) Connectors | 3 | 2 | 2 | 2 | 4 |
| PFC (Power Factor Correction) | Active PFC | Active PFC | Active PFC | Active PFC | Active PFC |
| Product Name | D9N63A 650W Modular ATX Power Supply | D9N51A High Efficiency Gaming Power Supply | P9S20A 500W Semi-Modular ATX Power Supply | H8B52A High Performance Modular ATX Power Supply | AF901A Premium Modular ATX Power Supply |
| Product Type | Power Supply | Power Supply | Power Supply | Power Supply | Power Supply |
| Protections | OCP / OVP / SCP | OCP, OVP, SCP, OTP | OCP / OVP / SCP / OTP | OCP / OVP / SCP | OCP, OVP, UVP, SCP, OTP |
| Rail Configuration | Single Rail | Single Rail | Single Rail | Single Rail | Single Rail |
| Remote Monitoring | No | No | No | N/A | No |
| RGB Lighting | No | No | No | No | No |
| SATA Power Connectors | 6 | 6 | 4 | 6 | 8 |
| Use Case | Gaming / Workstation | Gaming | Enterprise Server / Workstation / Gaming | Gaming / Workstation / Rack Server | Gaming / Workstation / Rack Server |
| Wattage | 650W | 650W | 500W | 850W | 850W |
| Weight | 4.5 lbs | 6.5 lbs | 7.5 lbs | 4 lbs | 4.5 lbs |
| Width | 8.6 inches | 5.9 inches | 5.91 inches | 6 inches | 5.8 inches |
| Zero RPM Mode | Yes | Yes | Yes | Yes | Yes |
Showing - of 0 Results
Questions & Answers
Q
What is the HPE Metered 3Ph 19.9kVA/L22-30P 24A/277V Outlets (30) RF-203P-HP/Vertical NA PDU (SKU D9N63A)?
A
The HPE Metered 3Ph 19.9kVA PDU (SKU D9N63A) is a vertical, 0U rack-mount power distribution unit offering 30 IEC outlets, 3-phase input with a NEMA L22-30P plug, and integrated metering and monitoring.
Q
What is the maximum power capacity of the HPE D9N63A metered PDU?
A
The PDU provides up to 19.9 kVA of three-phase power at 277 V, with a 24 A rating per phase for high-density rack deployments.
Q
Which input connector does the HPE RF-203P-HP PDU use?
A
It uses a NEMA L22-30P three-phase locking plug rated at 24 A to ensure secure, high-capacity power delivery.
Q
How many outlets does SKU D9N63A offer and what type are they?
A
This PDU features 30 IEC-60320 receptacles (C13/C19) configured to support mixed server and networking equipment.
Q
Does the HPE Metered PDU support 277 V input voltage?
A
Yes, the RF-203P-HP supports 208 V, 240 V and 277 V three-phase power inputs for North American data centers.
Q
What metering and monitoring features are included on the D9N63A PDU?
A
It provides per-phase current metering, total kWh consumption, outlet-level monitoring, and a local LCD display for real-time visibility.
Q
How can I monitor power remotely on the HPE Metered 3Ph PDU?
A
Remote monitoring is enabled via SNMP v1/v2c/v3, Telnet, SSH and a built-in web interface, with optional HPE IMC integration.
Q
Where is the RF-203P-HP PDU mounted in a server rack?
A
The PDU installs vertically in a standard 19″ rack using a 0U side-rail footprint to save U-space.
Q
What are the physical dimensions of the HPE vertical metered PDU?
A
Dimensions are approximately 1.7″ H × 49.5″ D × 2.8″ W (4.3 cm × 125.7 cm × 7.1 cm); weight is about 16 lb (7.3 kg).
Q
What warranty covers the HPE Metered 3Ph PDU SKU D9N63A?
A
HPE provides a 3-year limited hardware warranty, with optional extensions and support services available.
Q
Which management protocols are supported by the D9N63A PDU?
A
Supported protocols include SNMP v1/v2c/v3, Modbus TCP, Telnet, SSH and an embedded HTTPS web GUI.
Q
Is the HPE RF-203P-HP suitable for high-density data center environments?
A
Yes, its 19.9 kVA capacity, 30-outlet design and rack-space-saving vertical mount make it ideal for high-density racks.
Q
How does this PDU ensure balanced power distribution?
A
It offers phase-level metering and outlet grouping to distribute loads evenly and prevent phase-imbalance risks.
Q
Can multiple D9N63A PDUs be daisy-chained together?
A
No, each PDU requires an independent three-phase feed; daisy-chaining inputs is not supported for this model.
Q
What built-in safety features does the HPE Metered PDU include?
A
It includes per-phase overcurrent protection, leak detection, secure locking outlets and is UL/cUL and CE certified.
Q
How do I install the HPE RF-203P-HP vertical metered PDU?
A
Mount it vertically in the rack’s side-rail slots, secure with included brackets, connect the L22-30P input to your 3-phase source, and configure network settings via the front-panel LCD.