CAB-SPWR-30CM
SAVE $85.00
Featured Deal
Hand-picked by our procurement team for standout value. This unit is offered at our sharpest price on current stock, verified against live market rates.
Name:
2 In stock - Ready to Ship
Certified Refurbished
Professionally inspected, bench-tested, and firmware-verified, with configurations wiped. Restored to full working order and backed by our warranty.
3 Year Extended Warranty
Same-day Shipping
30-Day Money Back Guarantee
Shipping:
Payment:
3 Year Extended Warranty
Same-day Shipping
30-Day Money Back Guarantee
Need Additional Discount on Product?
Request a quote below - Get Exclusive Pricing and Support.
Shipping:
Payment:
PWR-C1-1100WAC-P
Cisco Catalyst 9300 Power Supply Module, 1100W AC, Hot-Swap,...
Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense
Enterprise Clients
Built Global. Stocked Local.
Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.
Buyer Protection on Every Order
Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.
Verified By Federal Bodies
Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.

Since 2016, Enterprise-Trusted
Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.
PWR-C1-1100WAC-P is the Cisco 1100 W AC Platinum-certified switch power supply module designed for Catalyst 9300-family platforms, including C9300 Series Switches, C9300L Series Switches, and C9300X Series Switches. It is an internal hot-plug C1 module installed in supported switch power bays, not an external adapter, UPS, battery, cable, PDU, power injector, or server power supply. The module fits procurement plans where the target switch requires a documented high-capacity AC supply, a populated secondary bay, or a like-for-like replacement aligned with Cisco power-supply tables. The 715 W and 350 W Platinum C1 supplies provide lower-capacity alternatives for chassis and PoE plans with reduced power demand. Buyers should confirm the exact chassis, power-bay population, facility power availability, and required PoE budget before selecting the 1100 W option. This verification helps ensure that the selected PSU matches both the supported platform and the intended deployment power profile.
PWR-C1-1100WAC-P provides 1100 W maximum rated output for supported Catalyst 9300 deployments. Cisco specifies 115 to 240 VAC input at 47 to 63 Hz, 12-6A input current, -56V output at 19.64A, 3754 BTU/hr output, and a minimum hold-up time of 20 ms at 115VAC. The unit uses an IEC 320-C16 input receptacle with a 15A-rated power-cord path and includes an internal fan for module cooling. Cisco describes Catalyst 9300 C1 power supplies as hot-swappable, although replacement procedures depend on available system power, StackPower conditions, full PoE+ loading, and correct handling of empty power bays. AC OK and PS OK LEDs provide local input and output status during installation and service checks. These indicators support basic verification that AC input is present and that the power-supply output is operating as expected after insertion or replacement.
PWR-C1-1100WAC-P is suited to purchasing teams and field-service groups that have already confirmed a supported C9300-family chassis, compatible AC input environment, high-power endpoint plan, and required redundancy strategy. For ecommerce classification, the product should remain categorized strictly as a switch power supply; unsupported router, firewall, wireless, transceiver, cable, storage, memory, server, adapter, PDU, UPS, battery, or injector attributes should be excluded unless a manufacturer source specifically identifies them. ORM Systems supplies this PSU in new and certified refurbished condition. Refurbished units are checked for output-voltage and ripple behavior under load, fan and thermal condition, and connector and latch integrity before dispatch. Buyers can send the target switch family and required quantity to ORM Systems for a quote and should record the C16 receptacle and 15A cord requirement as part of deployment planning. Maintaining those details in procurement records helps reduce specification errors and supports accurate installation, replacement, and spare-stock planning across Catalyst 9300-family environments.
PWR-C1-1100WAC-P price is is available on request. Get immediate quote.
Request bulk order quote for PWR-C1-1100WAC-P for additional pricing. Browse the full Catalyst 9300 Power Supplies series or explore all Cisco products.
PWR-C1-1100WAC-P supports Catalyst 9300-family wiring closets where access switches carry high endpoint power budgets. Engineers match the 1100 W Platinum AC module to the chassis series, verify the 115 to 240 VAC feed, and reserve the correct C16 and 15A cord path before staging hardware. The switch receives a documented power-supply PID for UPOE or dense PoE designs, while purchasing teams avoid substituting lower-wattage C1 modules during refresh work or spare fulfillment. Documented staging notes also support repeatable multi-site hardware audits.
A supported Catalyst 9300, C9300L, or C9300X chassis with two C1 power bays benefits from exact second-bay planning. PWR-C1-1100WAC-P gives operations teams a matched 1100 W AC Platinum module for redundancy layouts, hot-swap service events, and power-budget reviews. Staff confirm current draw, available facility power, StackPower behavior, and blank-cover handling before dispatch. The result is cleaner maintenance documentation and fewer field delays caused by wrong wattage, wrong receptacle, or unsupported substitute modules. Clear bay records also support faster receiving and return checks.
Enterprise spare inventory for Catalyst 9300-family access switches improves when high-capacity PSU records stay separated by exact wattage and certification level. This 1100 W Platinum AC supply belongs in bins assigned to supported high-PoE and multigigabit switch models rather than lower-wattage access platforms. Asset staff record C16 input details, 15A cord needs, module depth, and power-budget notes beside the spare. Receiving teams then verify label, latch, fan, and connector condition against the same operating requirement. This separation also simplifies audits across regional replacement shelves.
Mon–Fri: [09:00-16:00]
Avg. response under 30 mins
| Product Type | Switch Power Supply | Switch Power Supply | Switch Power Supply |
| Wattage | 1100W | 715W | 350W |
| Form Factor | Hot-Plug Module | Hot-Plug Module | Hot-Plug Module |
| 80 PLUS Certification | 80 Plus Platinum | 80 Plus Platinum | 80 Plus Platinum |
| Remote Monitoring | No Remote Monitoring | No Remote Monitoring | No Remote Monitoring |
| Input Voltage | 115 to 240 VAC, 47 to 63 Hz | 100 to 240 VAC, 47 to 63 Hz | 100 to 240 VAC, 47 to 63 Hz |
| Hot-Swap Capable | Hot-Swap | Hot-Swap | Hot-Swap |
| Efficiency Rating | Platinum-rated | Platinum-rated | Platinum-rated |
| Operating Temperature | 23 to 113 F (-5 to 45 C), up to 5000 ft | 23 to 113 F (-5 to 45 C), up to 5000 ft | 23 to 113 F (-5 to 45 C), up to 5000 ft |
| Product Name | 1100 W AC Platinum certified power supply module | 715 W AC Platinum certified power supply module | 350 W AC Platinum certified power supply module |
| Height | 1.58 in | 1.58 in | 1.58 in |
| Width | 3.25 in | 3.25 in | 3.25 in |
| Depth | 13.7 in | 12.20 in | 12.20 in |
| Weight | 3.1 lb (1.4 kg) | 2.6 lb (1.2 kg) | 2.3 lb (1.2 kg) |
Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.
New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 3 months, for dependable protection on every order. Coverage is clear, honoured in full, and confirmed on each product page.
If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.
Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.
Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.
dispatched quickly and shipped worldwide from regional hubs, fully tracked and insured.
Compatibility matched the high-power Catalyst 9300 models, and installation notes were clear.
Stable 1100 W AC module with clean labeling and a solid latch fit.
Useful for keeping redundant power plans consistent across supported C9300 sites.
The hot-swap guidance and power-budget review helped avoid a mismatched spare.
Refurbished unit arrived tested, labeled correctly, and ready for receiving checks.
Good support response on the C9300X compatibility question before purchase.
Worked well after verifying the 15A cord path and PSU slot plan.
PWR-C1-1100WAC-P is a Cisco 1100 W AC Platinum certified power supply module for supported Catalyst 9300-family switch power bays. It is an internal hot-plug C1 PSU, not a router, server, cable, adapter, transceiver, firewall, wireless, memory, storage, UPS, or battery product. Selection should start with the exact switch chassis and Cisco power-supply table.
PWR-C1-1100WAC-P should be categorized as a switch power supply. The item belongs with internal Catalyst 9300 C1 PSU modules and should not inherit router, transceiver, cable, wireless, adapter, storage, server, memory, firewall, PDU, UPS, battery, or power-injector attributes unless an authoritative manufacturer source specifically identifies that category.
Cisco documentation places PWR-C1-1100WAC-P in the Catalyst 9300-family C1 power-supply ecosystem, with support across C9300 Series Switches, C9300L Series Switches, and C9300X Series Switches where the chassis and power plan match. Buyers should still verify the exact switch model, power bay, and software or hardware documentation before purchase.
The documented maximum rated output for PWR-C1-1100WAC-P is 1100 W. Cisco lists the DC output as -56VDC at 19.64A, and the module should be selected only when that wattage class matches the switch model and total power budget. Do not substitute another wattage only because the enclosure family appears similar.
PWR-C1-1100WAC-P uses AC input rated at 115 to 240 VAC, 47 to 63 Hz. Cisco also lists input current as 12-6A. Facility power, circuit capacity, cord type, and local installation practices should be checked before deployment, especially when the module is used in a second bay or in a stack with shared power behavior.
The Cisco table lists IEC 320-C16 as the input receptacle for PWR-C1-1100WAC-P. This detail matters because the matching cord path differs between C1 power-supply wattages. Procurement and field teams should record the receptacle beside the SKU to avoid dispatching an incompatible AC power cord. Record this before shipping.
The power-supply data lists a 15A AC power cord path for PWR-C1-1100WAC-P. Cord inclusion and plug style should be confirmed with the seller, region, and order condition because ecommerce listings sometimes separate PSU modules and localized cords. The core product record should not invent a country-specific cable unless verified for that offer.
Cisco describes Catalyst 9300 C1 power supplies, including PWR-C1-1100WAC-P, as hot-swappable. Replacement still depends on available system power, StackPower behavior, full PoE load, and slot population. Technicians should follow Cisco service guidance and avoid leaving an opening empty after removing a supply or blank cover.
PWR-C1-1100WAC-P participates in Catalyst 9300 power-bay designs where one or two active modules are used in supported switches. Redundant behavior depends on chassis configuration, total load, and StackPower planning. The module should not be described as universal N+1 equipment outside the switch platform documentation. Use the host switch guide.
Cisco identifies AC OK and PS OK LEDs on the C1 supply assembly used by PWR-C1-1100WAC-P. These indicators help local technicians check AC input and DC output status after installation or service. LED state should be interpreted with the hardware guide rather than treated as remote monitoring capability.
PWR-C1-1100WAC-P itself should not be presented as a standalone remote-monitoring device. It is a power module installed inside supported Catalyst 9300-family switches. Any management visibility comes from the host switch platform and documented system behavior, not from an independent PSU network interface or separate monitoring controller.
Cisco notes that Catalyst 9300 C1 power-supply modules have internal fans, and that applies to PWR-C1-1100WAC-P. Cooling statements should stay limited to the module fan and the host switch airflow rules. Slot blanks and installed supplies also matter because open bays affect proper chassis airflow.
Cisco lists PWR-C1-1100WAC-P at 1.58 inches high, 3.25 inches wide, and 13.7 in deep. These are module dimensions for the supported switch power bay. Shipping box dimensions, pallet size, or rack-space claims should not be added unless a separate verified source provides them. Use separate verified logistics records.
The listed module weight for PWR-C1-1100WAC-P is 3.1 lb (1.4 kg). That value should be used as the product hardware weight, not as a shipping weight. If an ecommerce workflow needs packed shipment weight, the value should come from a verified logistics source or seller record.
PWR-C1-1100WAC-P is identified as an AC Platinum-certified power supply module. The product record may use 80 Plus Platinum and Platinum-rated language, but it should not invent a percentage efficiency number unless the exact-SKU source provides one. Certification language should match the Cisco naming and tables.
PWR-C1-1100WAC-P and PWR-C1-715WAC-P are both Cisco Catalyst 9300 C1 Platinum AC power-supply PIDs, but they target different wattage classes. PWR-C1-1100WAC-P is the 1100 W option, while PWR-C1-715WAC-P is a 715 W option. Selection should follow the switch model, PoE budget, redundancy plan, and Cisco compatibility table.
PWR-C1-1100WAC-P and PWR-C1-350WAC-P should not be treated as interchangeable only because both belong to the C1 power-supply family. PWR-C1-1100WAC-P is documented as 1100 W, while PWR-C1-350WAC-P serves a different wattage role. Match the PSU to chassis requirements, endpoint load, and second-bay plan before ordering. Confirm the PID before staging.
PWR-C1-1100WAC-P should remain separate from similarly named non-Platinum C1 power supplies. The -P suffix identifies the Platinum-certified version in the Cisco power-supply tables. Product content should preserve the full SKU, including suffixes, to avoid mixing different efficiency classes or catalog entries. That separation protects receiving accuracy.
PWR-C1-1100WAC-P is not an external desktop adapter or inline power brick. It is an internal hot-plug power supply module for supported Catalyst 9300-family switch bays. Records should avoid adapter, injector, laptop charger, or external PSU attributes unless the exact manufacturer documentation uses those terms for the item.
PWR-C1-1100WAC-P should not be routed to router or server content. Cisco positions it as a Catalyst 9300-family switch power-supply module. If a router, server, firewall, storage appliance, or wireless platform is involved, the item should be rejected for this category and sent to the correct product prompt.
For PWR-C1-1100WAC-P, the -P suffix is part of the exact Cisco manufacturer part number and identifies the Platinum-certified AC supply entry. The suffix should never be trimmed from the SKU, because similar C1 power-supply PIDs exist with different wattage or certification characteristics. Preserve it in every spreadsheet cell.
The power-supply schema should use N/A for output connectors on PWR-C1-1100WAC-P when no separate customer-facing connector is documented. The module installs into the supported switch power bay and feeds the switch internal power bus, so unsupported external outlet or cable-connector claims should be excluded. Keep outlet fields separate from PSU bays.
Use N/A for protections on PWR-C1-1100WAC-P unless an exact-SKU source documents named protection features. Generic over-voltage, short-circuit, surge, or thermal-protection claims should not be invented from category assumptions. Specification values should stay tied to Cisco data or another authoritative manufacturer source. This keeps the schema evidence based.
Cisco lists Catalyst 9300 power-supply operating conditions at 23 to 113 F, or -5 to 45 C, up to 5000 feet. That range should be used for PWR-C1-1100WAC-P with the same altitude context. Storage temperature or extended operating claims require separate exact-source support. Include the altitude note with the value.
Compliance content for PWR-C1-1100WAC-P should remain limited to verified standards from Cisco documentation, such as EMC references where listed. The product record should not add safety, environmental, telecom, military, medical, or country-specific approvals unless the exact source names those standards for this PSU family. Keep approvals grouped only when sourced.
PWR-C1-1100WAC-P is not a UPS and does not include a battery runtime specification. The power-supply schema should keep UPS capacity and battery runtime as N/A for this product. Adding backup-time claims would misclassify the part and create unsupported ecommerce content. Keep those UPS fields as N/A.
PWR-C1-1100WAC-P does not provide external output outlets like a PDU or UPS. It is an internal switch PSU that connects through the Catalyst power bay. The output outlets field should remain N/A unless a manufacturer source documents customer-facing outlets, which is not the case for this module.
The product name should reflect Cisco's documented wording: 1100 W AC Platinum certified power supply module. Ecommerce naming may add brand, Catalyst 9300 family, wattage, AC input, hot-swap form factor, and Platinum certification, but it should not add unsupported PoE budget, lifecycle, warranty, stock, or lead-time claims.
A suitable optimized name for PWR-C1-1100WAC-P identifies Cisco, Catalyst 9300, switch power supply module, 1100 W AC rating, hot-swap design, and 80 Plus Platinum class. Keep the SKU exact and avoid marketing language, unsupported compatibility expansion, or claims about price, availability, shipping speed, or warranty.
Refurbished PWR-C1-1100WAC-P content should focus on verifiable receiving and functional checks, such as output-voltage and ripple verification under load, fan and thermal review, connector inspection, and latch condition. It should not invent remaining life, original warranty, unused status, or factory-new condition unless the seller record proves it.
Buyers should confirm the exact Catalyst chassis, power-supply bay type, 1100 W requirement, input voltage, receptacle, cord path, redundancy plan, and StackPower context before ordering PWR-C1-1100WAC-P. This is especially important when several C1 modules appear similar but differ by wattage, efficiency class, or connector requirement.
The full string PWR-C1-1100WAC-P identifies a specific Cisco manufacturer part number. Removing suffixes, changing punctuation, or dropping characters risks matching a different C1 power-supply module. Spreadsheet storage should keep the SKU as text so Excel does not alter the identifier or remove meaningful characters. Use text storage in Excel.
PWR-C1-1100WAC-P is relevant to high-capacity access-switch power plans, but budget calculations should use the target switch model, installed endpoint load, redundant module plan, and Cisco power documentation. The product record should not state a guaranteed PoE budget unless the exact chassis table supports that claim.
Exact-SKU Cisco documentation should be preferred for PWR-C1-1100WAC-P, followed by official Catalyst 9300 hardware guides and Cisco power-supply tables. Distributor or marketplace pages are secondary checks for identifiers and condition only. User-generated, scraped, or generic PSU pages should not override the manufacturer source. Exact manufacturer tables take priority.
PWR-C1-1100WAC-P should be rejected only if research shows the item is not a power supply or the provided identifier resolves to a different product category. The same rejection rule applies to routers, switches as complete systems, servers, cables, adapters, transceivers, firewalls, storage, memory, wireless products, and other non-PSU hardware.