FEATURED DEAL

Name:

DS-C9396S-96ESK9

Description:
Cisco DS-C9396S-96ESK9 MDS 9396S 96-Port 16G FC Switch, Shortwave Optics, Port-Side Exhaust
Rating:
0(0)

Added to cart 28 times recently

Availability:

Ready to Ship

Brand:
Cisco
GTIN:
0882658827211
Condition:
Warranty:
90
List Price:

$138,986.40

Price:

$69,493.2050% off

Quantity:

1
100% Genuine Guaranteed
Global Delivery
Business Terms / PO Accepted
Rated 4.8 out of 5 on Trustpilot

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow
ds-c9396s-96esk9 cisco ds-c9396s-96esk9 mds 9396s 96-port 16g fc switch, shortwave optics, port-side exhaust
Rated 4.8 out of 5 on Trustpilot

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow

Need Additional Discount on Product?

Request a quote below - Get Exclusive Pricing and Support.

Qty:

Exclusive Bulk Discounts tailored to your order size

Priority Processing with a dedicated account manager

Fast Response: Get your custom quote within 5-10 minutes during business hours

Holiday Bonus: Submissions on holidays receive priority handling the next business day

DS-C9396S-96ESK9

Original Stock
Ready to Ship

Cisco DS-C9396S-96ESK9 MDS 9396S 96-Port 16G FC Switch, Shor...

$138,986.40 $69,493.2050% off

Get a Quote

Trusted by the Highest-Stakes Buyers

Federal agencies and Fortune 500 operations source through ORM Systems.

US Government & Defense

  • United States Army
  • United States Embassy
  • United States Marine Corps
  • Bureau of Alcohol, Tobacco, Firearms and Explosives

Enterprise Clients

  • Novartis
  • Siemens Healthineers
  • ExxonMobil

Built Global. Stocked Local.

Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.

4Global Offices
25+Distribution Points
100+Countries Served

Buyer Protection on Every Order

Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.

Verified By Federal Bodies

Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.

  • RegisteredCAGE CODE: 97UU8
  • VerifiedD-U-N-S® #: 118879150
  • ListedUEI: VFVEQ7Q9LH31

Since 2016, Enterprise-Trusted

Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.

10+Years Operating
20,000+Clients Served
150K+SKUs Available

Optical SAN Connectivity for Data Center Storage

DS-C9396S-96ESK9 provides 96 enabled 16G FC ports with bundled DS-SFP-FC16G-SW shortwave optics and port-side exhaust airflow. The fixed optical architecture connects storage devices, servers and neighboring fabric switches without a separate uplink card. The Cisco MDS 9396S 16G Multilayer Fabric Switch occupies two rack units and serves departmental SANs or enterprise data center fabric edges. Hardware-enforced VSAN isolation and zoning separate storage environments within the physical fabric. Dual internal AC power supports the chassis, while the exhaust orientation moves air toward the port side. The discontinued DS-C9396S-96EK9 has the same enabled-port configuration but does not include the shortwave optics bundle.

DS-C9396S-96ESK9 price for new stock is is available on request. Get immediate quote. DS-C9396S-96ESK9 refurb price is $69,493.20.

Request bulk order quote for DS-C9396S-96ESK9 for additional pricing. Browse the full Cisco MDS 9300 Switches series or explore all Cisco products.

Technical Details

800W maximum consumption under fully populated, 16G, full-traffic operation at 25°C establishes the electrical planning figure. 500 buffer credits per port are available without the optional Enterprise license, so distance-sensitive connections require credit requirements to be checked before deployment. DS-C9396S-96ESK9 supports stateful process restart and In-Service Software Upgrades for software maintenance while FC ports carry traffic. Administrators can use the Cisco MDS 9000 Family CLI through the serial console or SSHv2, with Cisco Prime DCNM providing centralized SAN management. SNMPv3 also supports monitoring through Ethernet or in-band IP over FC. Power On Auto Provisioning automates image and configuration installation, while virtual output queuing addresses head-of-line blocking.

Ordering

DS-C9396S-96ESK9 is offered new sealed or certified refurbished, with an ORM warranty of up to 3-year extended on new units and up to 1 year on certified refurbished units; returns cover 30 days on every condition, terms apply. Certified refurbished units are inspected and bench-tested for power-on and POST, rated-speed port links, optics bay recognition, PSU and fan status, and clean boot; firmware is verified and configurations are wiped to factory default. Specify condition, quantity and required accessories on the purchase order, including enterprise and volume requirements. POs are accepted, government orders qualify for Net-30, and RMA includes advance replacement, with regional stock and RMA coverage across the UK, EU, US and MEA.

Buying Notes

Buying NotesKey Specs

Advanced features require licensing

Inter-VSAN Routing and QoS require the optional M9300ENT1K9 Enterprise Package. Advanced SAN management uses DCNM-SAN-M93-K9 or an Enterprise/DCNM bundle; advanced software packages arrive uninstalled and require license-key installation.

Security maintenance has ended

Continuing security-remediation requirements warrant replacement review: DS-C9396S-96ESK9 passed its June 9, 2025 vulnerability/security-support milestone. DS-C9396T-96ETK9 is the designated replacement for the bundled port-side exhaust configuration.

Grid redundancy requires higher voltage

Power-grid redundancy requires 180-264V AC on the dual-supply configuration. Lower-voltage installations should not treat the two installed power inputs as equivalent to the higher-voltage 1+1 redundancy arrangement.

Key Specs

Key SpecsKey Spec Values

Operating System

NX-OS

Port Configuration

96 active 16G FC ports

Max Power Draw

800W

Cooling

Port-side exhaust

Lifecycle Status

End of sale June 10, 2022

Replacement PID

DS-C9396T-96ETK9

DS-C9396S-96ESK9 Specifications

Manufacturer Part Number
DS-C9396S-96ESK9
Brand
Cisco
Series
MDS 9396S
Use Case
Data Center
Management Type
Managed
Software Image
NX-OS
Power Input
Internal AC PSU
SFP+ Ports
96 x 16G FC
Form Factor
Rack-Mount 2U
Input Voltage
100-240V AC
Power Consumption
800W
Redundant PSU
Yes
Cooling
Fan trays / Port-side exhaust
Operating Temperature
0°C to 40°C
Cisco Warranty
1 year, subject to eligibility; Cisco service ends June 30, 2027
Certifications
CE Marking / UL 60950 / CAN/CSA-C22.2 No. 60950 / EN 60950 / IEC 60950 / FCC Part 15 (CFR 47) Class A / ICES-003 Class A / EN 55022 Class A / CISPR 22 Class A
Height
86.4 mm
Width
442.5 mm
Depth
565.9 mm
Weight
17.8 kg

Best For

Fabric Edge Expansion

An existing storage fabric needs additional edge connections while retaining aggregated links toward its core. PortChannel supports 16 physical links in one logical bundle, and NPV operation supports F-port channeling. Before the PO, specify the required inter-switch connections and verify the planned fabric operating mode.

NVMe Storage Staging

A storage team is staging NVMe over FC equipment before introducing it into an established SAN. FC-NVMe requires NX-OS 8.2(1) or later on the MDS 9396S. Before ordering, identify the intended software release and confirm interoperability across the storage devices, host adapters and existing fabric.

Spare Component Planning

A maintenance purchase must include chassis components as well as the replacement switch. DS-CAC-1200W-E= is the port-side exhaust power-supply spare, and DS-C96S-FAN-E= is the matching fan-tray spare. Specify the required spare quantities and airflow orientation as separate purchase-order lines rather than assuming component spares accompany the chassis.

Not Suitable If

32G storage fabric connections

DS-C9396S-96ESK9 provides 16G FC connections, not 32G. DS-C9396T-96ETK9 is its replacement with 96 active ports and bundled 32G optics, retaining port-side exhaust airflow.

Port-side intake cooling requirements

DS-C9396S-96ESK9 exhausts air through the port side. DS-C9396T-96ITK9 provides the intake orientation with 96 active ports and bundled 32G optics, also changing the connection speed.

Product Comparison Table

Cisco DS-C9396S-96ESK9 MDS 9396S 96-Port 16G FC Switch, Shortwave Optics, Port-Side ExhaustDS-C9396S-96ESK9Cisco DS-C9396S-48E8K9 MDS 9396S 48-Port 16G Fibre Channel Switch With DS-SFP-FC8G-SW OpticsDS-C9396S-48E8K9Cisco DS-C9396S-48ESK9 MDS 9396S 48-Port 16G Fibre Channel Switch, Port-Side ExhaustDS-C9396S-48ESK9Cisco DS-C9396T-48IK9 MDS 9396T 48-Port 32G Fibre Channel Switch, Port-Side IntakeDS-C9396T-48IK9Cisco DS-C9396V-48EK9 MDS 9396V 48-Port 64Gbps Fibre Channel SwitchDS-C9396V-48EK9
Depth565.9 mm565.9 mm565.9 mm565.9 mm607.3 mm
Form FactorRack-Mount 2URack-Mount 2URack-Mount 2URack-Mount 2URack-Mount 2U
Height86.4 mm86.4 mm86.4 mm86.1 mm86.4 mm
Manufacturer Part NumberDS-C9396S-96ESK9DS-C9396S-48E8K9DS-C9396S-48ESK9DS-C9396T-48IK9DS-C9396V-48EK9
Power Consumption800W700W700W246W (idle without optics)880W
Weight17.8 kg17.8 kg17.8 kg18.88 kg20 kg
Width442.5 mm442.5 mm442.5 mm442.5 mm442.3 mm

Compliance & Warranty

ISO 27001
ISO 45001
RoHS
REACH
FCC
CE
UKCA
VCCI
ISO 9001
ISO 14001

100% Genuine Product Guarantee

Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.

Up to 3-Year Warranty Coverage

New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 3 months, for dependable protection on every order. Coverage is clear, honoured in full, and confirmed on each product page.

Hassle-Free RMA & Returns

If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.

Rigorously Tested & Quality Assured

Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.

Expert Technical Support

Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.

Fast Global Delivery

dispatched quickly and shipped worldwide from regional hubs, fully tracked and insured.

Questions & Answers

What does the DS-C9396S-96ESK9 part number identify?

DS-C9396S-96ESK9 identifies an MDS 9396S 16G FC switch with 96 active ports, port-side exhaust and bundled shortwave optics. DS-C9396S names the switch model, 96 identifies the enabled-port count, E identifies exhaust airflow, and S distinguishes the 16G shortwave optics bundle from the chassis-only configuration.

How is the Cisco MDS 9396S managed?

Cisco MDS 9396S management uses the serial-console CLI, SSHv2 over Ethernet, Cisco Prime DCNM, SNMPv3 and SMI-S. SNMPv3 also operates through in-band IP over FC. The chassis provides an out-of-band Ethernet management connection, while scriptable CLI and DCNM web services support automation workflows.

Is DS-C9396S-96ESK9 discontinued?

Yes, DS-C9396S-96ESK9 reached end of sale on June 10, 2022, with eligible Cisco support ending June 30, 2027. The service-contract renewal deadline was September 5, 2026. DS-C9396T-96ETK9 is the replacement for this optics-bundled exhaust configuration; remaining manufacturer support depends on an existing eligible entitlement.

What conditions and warranties does ORM offer for DS-C9396S-96ESK9?

New sealed and certified refurbished DS-C9396S-96ESK9 units are offered by ORM Systems. ORM warranties are up to 3-year extended for new units and up to 1 year for certified refurbished units. Cisco's separate 1-year warranty is eligibility-dependent and bounded by June 30, 2027. Every condition includes 30-day returns; terms apply.

Which licenses are needed for DS-C9396S-96ESK9?

DS-C9396S-96ESK9 includes 96 enabled ports; advanced capabilities require separate software licenses. M9300ENT1K9 adds the Enterprise Package, DCNM-SAN-M93-K9 adds advanced SAN management, and M93ENTDCNM-K9 combines those packages. Advanced packages arrive uninstalled, with a product authorization key used to obtain and install the appropriate license-key file.

What is the difference between DS-C9396S-96ESK9 and DS-C9396S-96EK9?

DS-C9396S-96ESK9 includes 16G shortwave optics, whereas DS-C9396S-96EK9 is the configuration without that optics bundle. Both have 96 enabled ports and port-side exhaust, and both are discontinued. The bundled model suits legacy replacements requiring accompanying optics; the unbundled model suits installations retaining compatible optical inventory.

What is the difference between DS-C9396S-96ESK9 and DS-C9396S-96IK9?

DS-C9396S-96ESK9 uses port-side exhaust airflow, whereas DS-C9396S-96IK9 uses port-side intake. Exhaust moves air toward the ports; intake draws air through them. Both configurations are discontinued. Existing rack airflow determines which legacy chassis orientation fits, so exhaust-oriented installations and intake-oriented installations require different configurations.

What is the difference between DS-C9396S-96ESK9 and DS-C9396T-96ETK9?

DS-C9396S-96ESK9 bundles 16G optics, while its replacement DS-C9396T-96ETK9 bundles 32G optics. Both configurations have 96 active ports and port-side exhaust. The discontinued 16G model addresses exact-model requirements in existing fabrics; the 32G replacement suits purchases moving storage connections to the higher-speed generation rather than extending the older configuration.

What power requirements does DS-C9396S-96ESK9 have?

DS-C9396S-96ESK9 uses dual internal AC power and has an 800W maximum consumption figure for a fully populated configuration at full 16G traffic load and 25°C. Nominal input is 100-240V AC. Power-grid redundancy specifically requires 180-264V AC, so feed voltage must be included in the electrical review.

How many buffer credits does the Cisco MDS 9396S support?

Cisco MDS 9396S supports 500 buffer credits per port without the Enterprise license and 4095 per port with the optional Enterprise license. These are per-port limits, not a chassis-wide total. Distance-sensitive FC connections should be assessed against the installed license before the switch and software are specified together.