Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense
Enterprise Clients
Featured Deal
Hand-picked by our procurement team for standout value. This unit is offered at our sharpest price on current stock, verified against live market rates.
Name:
Ready to Ship
Certified Refurbished
Professionally inspected, bench-tested, and firmware-verified, with configurations wiped. Restored to full working order and backed by our warranty.
$3,181.92
$1,509.3852.6% off
Quantity:
DS-C9710
Cisco DS-C9710 MDS 9700 SAN Chassis Switch
Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense




Enterprise Clients
Built Global. Stocked Local.
Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.
Buyer Protection on Every Order
Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.
Verified By Federal Bodies
Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.
Since 2016, Enterprise-Trusted
Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.
DS-C9710 is a chassis-only SAN director ordering option with cooling included and power supplies excluded. Eight I/O slots accommodate separately selected storage-networking cards, while two supervisor positions provide space for the control hardware. The MDS 9710 Multilayer Director serves enterprise data center storage networks rather than fixed-port Ethernet access deployments. DS-C9710-V2K9 differs by including four DS-CAC97-3KW supplies in a configured hardware bundle. Within the MDS 9700 Series Multilayer Directors, connectivity and port speeds depend on the installed I/O modules; the chassis part number does not represent a populated switch.
DS-C9710 price for new stock is is available on request. Get immediate quote. DS-C9710 refurb price is $1,509.38.
Request bulk order quote for DS-C9710 for additional pricing. Browse the full Cisco MDS 9700 Directors series or explore all Cisco products.
24000 Gbps maximum Fibre Channel switching capacity is a populated-chassis capability, not throughput delivered by the bare chassis. FSPF provides fabric multipathing, while VSANs and hardware-enforced zoning separate storage traffic. DS-C9710 supports CLI access, SNMPv3 monitoring and centralized NDFC management through installed operating hardware. Front-to-back airflow determines cabinet orientation, and POST plus online diagnostics support hardware checks before production connections are made. Supervisor and switching-fabric selections determine the operating configuration, so a chassis purchase must be distinguished from a complete director assembly.
Order DS-C9710 new sealed or certified refurbished, with up to 3-year extended warranty coverage on new units and up to 1 year on certified refurbished units; returns are available for 30 days on every condition, terms apply. Certified refurbished chassis are inspected and bench-tested, including module bay recognition and DS-C9710-FAN status checks. Specify condition, quantity and included components on the purchase order, and keep Cisco's limited hardware warranty separate from ORM's coverage. ORM accepts POs, provides Net-30 for government purchases and supports RMA with advance replacement; identify enterprise and volume quantities together when defining the order.
| Key Specs | Key Spec Values |
|---|---|
Operating System | NX-OS with installed supervisors. |
Port Configuration | Chassis only / eight I/O slots. |
Cooling | 3 DS-C9710-FAN trays. |
Replaces | DS-C9509 / DS-C9509-HDS: 2014-04-28; DS-C9513: 2016-10-31. |
Ships Without | Power supplies. |
When replacing discontinued DS-C9509, DS-C9509-HDS or DS-C9513 hardware, the replacement chassis is DS-C9710. Treat chassis replacement and hardware reuse as separate purchase decisions rather than assuming the original assembly transfers unchanged. Confirm the reusable inventory and specify every remaining component before issuing the purchase order.
When staging a director with Fabric-3 hardware, DS-X97-SF4-K9 supervisors must pair with DS-X9710-FAB3 modules. Different supervisor or fabric generations cannot remain mixed except during migration. Reconcile the installed generation and software release with the intended build, then specify matching components for the staging purchase order.
More than eight I/O slots
DS-C9710 provides eight I/O slots. DS-C9718 provides sixteen and occupies 26 rack units, versus fourteen for DS-C9710, so the larger chassis requires different rack-space planning.
A populated base hardware bundle
DS-C9710 excludes power supplies. DS-C9710-V2K9 bundles two DS-X97-SF4-K9 supervisors, three DS-X9710-FAB3 modules and four DS-CAC97-3KW supplies; I/O modules still require separate selection.
Mon–Fri: [09:00-16:00]
Avg. response under 30 mins
| Depth | 864 mm | 813 mm | 864 mm | 889 mm | 468 mm |
| Form Factor | Chassis | Chassis | Chassis | Chassis | Chassis |
| Height | 619 mm | 396.2 mm | 619 mm | 1149 mm | 623 mm |
| Manufacturer Part Number | DS-C9710 | DS-C9706 | DS-C9710-4BSK9 | DS-C9718 | DS-C9509-2AK9 |
| Width | 439 mm | 439 mm | 439 mm | 439 mm | 441 mm |
Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.
New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 3 months, for dependable protection on every order. Coverage is clear, honoured in full, and confirmed on each product page.
If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.
Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.
Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.
dispatched quickly and shipped worldwide from regional hubs, fully tracked and insured.
DS-C9710 identifies the MDS 9710 chassis with fans included and power supplies excluded. The 9710 portion identifies the director model, not an installed port count. The complete part number orders chassis hardware rather than a populated switch bundle, so operating components require separate selection.
DS-C9710 supports a populated configuration of 384 Fibre Channel ports, but the chassis-only order does not provide installed storage ports. Eight I/O positions accommodate the selected switching modules. Specify the required connectivity and module population separately rather than treating the chassis capacity as an included port configuration.
The MDS 9700 director is managed through the CLI, NDFC or DCNM, and integration with third-party storage-management tools. Installed operating hardware provides serial-console and Ethernet CLI access, SSH, SNMPv3 and in-band IP over Fibre Channel. Qualified mainframe configurations also support FICON CUP management through their storage interfaces.
Cisco has not announced an end-of-sale date for MDS 9700. DS-C9710 remains the chassis ordering option for the MDS 9710 director. Discontinued supervisors, switching modules and traditional software licenses have separate lifecycle dates, so the complete purchase configuration must be evaluated independently of the chassis.
DS-C9710 is offered new sealed or certified refurbished, with ORM warranties of up to 3-year extended coverage for new units and up to 1 year for refurbished units. Returns are available for 30 days on every condition; terms apply. Cisco's limited hardware warranty is separate from ORM's order coverage.
DS-C9710 advanced features use Advantage or Premier subscriptions, with 1-, 3-, 5- or 7-year terms and a one-year minimum. Advantage includes Enterprise features and NDFC; Premier adds SAN Analytics. Mainframe features are included from NX-OS 9.4.1a. Subscription entitlements are assigned to the customer's Smart Account.
DS-C9710 replaces DS-C9509, DS-C9509-HDS and DS-C9513. The DS-C9509 and DS-C9509-HDS end-of-sale date was April 28, 2014; DS-C9513 ended sale October 31, 2016. These are discontinued predecessors, not current alternatives. Verify component reuse separately when defining the replacement director's purchase configuration.
DS-C9710 cannot retain mixed supervisor generations or mixed switching-fabric generations except during migration. DS-X9710-FAB3 modules pair with DS-X97-SF4-K9 supervisors. An upgrade purchase therefore needs a coordinated hardware plan rather than an isolated component substitution; reconcile the complete installed inventory before specifying replacement control and fabric hardware.
DS-C9710 supports configurable power redundancy across eight supply bays, but power supplies are excluded from the chassis-only order. DS-CAC97-3KW is the 3000W AC option. Determine the required quantity from the installed hardware, electrical input and intended redundancy configuration, then include the selected supplies on the purchase order.
DS-C9710 excludes power supplies, whereas DS-C9710-V2K9 includes four DS-CAC97-3KW supplies, two DS-X97-SF4-K9 supervisors and three DS-X9710-FAB3 modules. I/O modules remain a separate selection. DS-C9710 suits a chassis-focused order; DS-C9710-V2K9 suits a purchase that also requires the bundled control, fabric and AC power hardware.
DS-C9710 accommodates eight I/O modules and 384 Fibre Channel ports, while DS-C9718 accommodates sixteen I/O modules and 768 Fibre Channel ports. The chassis heights are fourteen and 26 rack units respectively. DS-C9710 suits the smaller director footprint; DS-C9718 suits a purchase requiring greater single-chassis module and port capacity.
The MDS 9710 Multilayer Director occupies fourteen rack units and uses front-to-back airflow. Maintain 177.8 mm of clearance at both the front and rear air vents. Confirm cabinet depth, mounting provisions and ventilation space before ordering; rack height alone does not establish that the chassis fits the intended enclosure.