FEATURED DEAL

Name:

DS-C9509-2K9

Description:
Cisco DS-C9509-2K9 MDS 9509 9-Slot Modular SAN Chassis Switch
Rating:
0(0)

Added to cart 28 times recently

Availability:

Ready to Ship

Brand:
Cisco
GTIN:
4063403429300
Condition:
100% Genuine Guaranteed
Global Delivery
Business Terms / PO Accepted
Get a Quote
Rated 4.8 out of 5 on Trustpilot

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow
ds-c9509-2k9 cisco ds-c9509-2k9 mds 9509 9-slot modular san chassis switch
Rated 4.8 out of 5 on Trustpilot

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow

Need Additional Discount on Product?

Request a quote below - Get Exclusive Pricing and Support.

Qty:

Exclusive Bulk Discounts tailored to your order size

Priority Processing with a dedicated account manager

Fast Response: Get your custom quote within 5-10 minutes during business hours

Holiday Bonus: Submissions on holidays receive priority handling the next business day

DS-C9509-2K9

Original Stock
Ready to Ship

Cisco DS-C9509-2K9 MDS 9509 9-Slot Modular SAN Chassis Switc...

Trusted by the Highest-Stakes Buyers

Federal agencies and Fortune 500 operations source through ORM Systems.

US Government & Defense

  • United States Army
  • United States Embassy
  • United States Marine Corps
  • Bureau of Alcohol, Tobacco, Firearms and Explosives

Enterprise Clients

  • Novartis
  • Siemens Healthineers
  • ExxonMobil

Built Global. Stocked Local.

Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.

4Global Offices
25+Distribution Points
100+Countries Served

Buyer Protection on Every Order

Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.

Verified By Federal Bodies

Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.

  • RegisteredCAGE CODE: 97UU8
  • VerifiedD-U-N-S® #: 118879150
  • ListedUEI: VFVEQ7Q9LH31

Since 2016, Enterprise-Trusted

Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.

10+Years Operating
20,000+Clients Served
150K+SKUs Available

Storage Fabric Expansion for Data Center Racks

DS-C9509-2K9 is a modular SAN director base configuration containing the MDS 9509 chassis, two DS-X9530-SF2-K9 Supervisor-2 modules and two DS-CAC-3000W AC power supplies. Its nine-slot architecture separates control functions from the switching or services cards selected for storage connectivity; the bundle does not include a fixed bank of storage ports. The Cisco MDS 9500 Series Multilayer Directors family serves large data center storage networks, with the connection inventory determined by installed cards and optical interfaces. Unlike the discontinued DS-C9509 chassis-only configuration, this bundle includes its control and power components. A matching chassis identifier therefore does not establish the installed port speeds, card population or optical connections. The enclosure occupies 14RU in a standard equipment rack, making cabinet allocation part of the hardware selection.

DS-C9509-2K9 price is is available on request. Get immediate quote.

Request bulk order quote for DS-C9509-2K9 for additional pricing. Browse the full Cisco MDS 9500 Directors series or explore all Cisco products.

Technical Details

16 speed-matched physical links can form a PortChannel, allowing SAN interconnects to span different switching cards rather than concentrating the logical connection on one card. FSPF supports load balancing across 16 equal-cost Fiber Channel paths. VSANs separate logical storage fabrics on shared hardware, while zoning controls device visibility within those fabrics. DS-C9509-2K9 supports CLI administration over SSH, Telnet or serial console, alongside Device Manager, Cisco DCNM and third-party management integrations. The Cisco MDS 9000 Family also provides virtual output queuing and per-port bandwidth reservation for storage traffic control. Active and standby control functions support stateful failover, and failed software processes can restart independently. Nine fans provide active cooling within an operating range of 0°C to 40°C. These are storage-fabric capabilities, not a substitute for fixed Ethernet access ports; electrical consumption and available connections depend on the populated hardware configuration.

Ordering

ORM Systems offers DS-C9509-2K9 in new sealed and certified refurbished condition; specify the condition, included components and quantities before issuing the purchase order. Certified refurbished units are inspected and bench-tested for power-on and POST, clean boot, module bay recognition, PSU status and fan status, with firmware verified and configurations wiped to factory default. ORM warranty coverage is up to a 3-year extended warranty on new units and up to 1 year on certified refurbished units, with 30-day returns on every condition, terms apply; Cisco warranty and service ended July 31, 2016. PO accepted, Net-30 for government and RMA with advance replacement support enterprise and volume orders, with regional stock and RMA across UK, EU, US and MEA.

Buying Notes

Buying NotesKey Specs

Verify optional software entitlements

DS-C9509-2K9 requires separate entitlement checks for optional features: Enterprise Package M9500ENT1K9 and Mainframe Package M9500FIC1K9 are distinct software packages, not a license tier encoded by this hardware bundle.

Follow the full migration

Migration planning for DS-C9509-2K9 must go beyond the discontinued DS-C9509-2AK9 and DS-C9710-1K9 bundles; DS-C9710-V2K9 is the current base configuration at the end of that replacement chain.

Specify storage optics separately

Short-reach 10G Fiber Channel connectivity requires DS-X9704 switching cards and compatible DS-X2-FC10G-SR optics. DS-X9704 provides four ports; include the required card and transceiver quantities in the configured order.

Account for input-voltage derating

DS-CAC-3000W delivers 1400W at 100V AC but 3000W at 200V AC. Size the populated chassis against the output available at the actual input voltage before specifying feed capacity.

Key Specs

Key SpecsKey Spec Values

Operating System

NX-OS

Port Configuration

7 switching bays; no fixed storage ports

Cooling

9 fans

Lifecycle Status

End of sale August 1, 2011

Replacement PID

DS-C9710-V2K9

DS-C9509-2K9 Specifications

Manufacturer Part Number
DS-C9509-2K9
Brand
Cisco
Series
MDS 9509
Use Case
Data Center
Management Type
Managed
Software Image
NX-OS
Layer
Layer 2
Routing Protocols
FSPF
Power Input
Internal AC PSU
Form Factor
Chassis
Input Voltage
100-240V AC
Primary PSU
DS-CAC-3000W
Redundant PSU
Yes
Cooling
9 fans
Operating Temperature
0°C to 40°C
Cisco Warranty
Ended July 31, 2016
Certifications
UL 60950 / IEC 60950 / EN 60950 / FCC Part 15 Class A / ICES-003 Class A / FIPS 140-2 Level 2
Height
623 mm
Width
441 mm
Depth
468 mm
Weight
78 kg

Best For

Storage Density Expansion

When an existing SAN needs additional storage connection density, the MDS 9509 offers seven switching or services bays rather than a fixed access-port inventory. Slot allocation must account for the required card mix and occupied positions. Specify each installed card, its port count and the corresponding optical interfaces before the PO.

SAN Lab Staging

During SAN lab preparation, a port assigned as a SPAN destination cannot carry normal storage traffic at the same time. Monitoring therefore changes the usable connection plan independently of chassis size. Reserve the required analyzer connection and confirm the remaining production-facing port inventory before issuing the PO.

Not Suitable If

Cisco-backed service coverage

Cisco support for DS-C9509-2K9 ended July 31, 2016. For a current migration purchase, consider DS-C9710-V2K9; its control and fabric configuration differs from the legacy bundle.

Fixed storage ports included at delivery

DS-C9509-2K9 is a base configuration without installed storage switching cards or optics. A ready-to-connect SAN requires those components to be explicitly included and matched to the retained control configuration.

Product Comparison Table

Cisco DS-C9509-2K9 MDS 9509 9-Slot Modular SAN Chassis SwitchDS-C9509-2K9Cisco DS-C9513 MDS 9513 13-Slot SAN Director Chassis SwitchDS-C9513Cisco DS-C9509-2AK9 MDS 9509 Modular SAN Chassis SwitchDS-C9509-2AK9Cisco DS-C9513-2K9 MDS 9513 13-Slot Fiber Channel Chassis SwitchDS-C9513-2K9Cisco DS-C9148S-12PK9 MDS 9148S 12-Port 16G Fibre Channel SwitchDS-C9148S-12PK9
Depth468 mm711 mm468 mm711 mm415 mm
Form FactorChassisChassisChassisChassisRack-Mount 1U
Height623 mm623 mm623 mm623 mm43.7 mm
Manufacturer Part NumberDS-C9509-2K9DS-C9513DS-C9509-2AK9DS-C9513-2K9DS-C9148S-12PK9
Weight78 kg45.4 kg.78 kg170.1 kg9 kg
Width441 mm441 mm441 mm441 mm435.9 mm

Compliance & Warranty

ISO 27001
ISO 45001
RoHS
REACH
FCC
CE
UKCA
VCCI
ISO 9001
ISO 14001

100% Genuine Product Guarantee

Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.

Up to 3-Year Warranty Coverage

New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 3 months, for dependable protection on every order. Coverage is clear, honoured in full, and confirmed on each product page.

Hassle-Free RMA & Returns

If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.

Rigorously Tested & Quality Assured

Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.

Expert Technical Support

Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.

Fast Global Delivery

dispatched quickly and shipped worldwide from regional hubs, fully tracked and insured.

Questions & Answers

What does the DS-C9509-2K9 part number mean?

DS-C9509-2K9 identifies an MDS 9509 base configuration containing two DS-X9530-SF2-K9 Supervisor-2 modules and two DS-CAC-3000W AC supplies. DS-C9509 identifies the chassis family, while -2K9 distinguishes this populated control-and-power bundle. Storage switching cards and optical transceivers are separate components, so the suffix does not specify a fixed data-port count.

How is DS-C9509-2K9 managed?

DS-C9509-2K9 is managed through the CLI over serial console, SSH or Telnet, plus Device Manager GUI, Cisco DCNM and third-party integrations through its web services API. Legacy Cisco Fabric Manager also includes a Web Client for browser-based monitoring. SNMP supports external management applications rather than storage data forwarding.

Is DS-C9509-2K9 end of life?

DS-C9509-2K9 is discontinued: end of sale was August 1, 2011, and Cisco support ended July 31, 2016. The original replacement, DS-C9509-2AK9, is also discontinued, as is the later DS-C9710-1K9 bundle. The replacement chain now reaches the current DS-C9710-V2K9 base configuration.

What condition and warranty does ORM Systems offer for DS-C9509-2K9?

ORM Systems offers DS-C9509-2K9 new sealed with up to a 3-year extended warranty or certified refurbished with up to 1 year. Every condition includes 30-day returns, terms apply. Certified refurbished units are inspected and bench-tested, firmware verified and wiped to factory default. Cisco warranty coverage and service ended July 31, 2016.

Which software licenses apply to DS-C9509-2K9?

DS-C9509-2K9 supports optional Enterprise Package M9500ENT1K9 and Mainframe Package M9500FIC1K9 feature licenses, with optional features requiring separate entitlement verification. SAN Extension over IP M9500EXT1AK9 applies to one DS-X9304-18K9 Multiservice Module. Specify required software entitlements independently of the chassis identifier and installed-card inventory when preparing the purchase order.

How are the DS-C9509-2K9 power supplies rated?

DS-C9509-2K9 includes two DS-CAC-3000W AC supplies, each rated for 3000W output at 200V AC and 1400W at 100V AC. The chassis supports redundant power operation. Those ratings describe supply output, not the director's electrical consumption, so size power feeds for the populated hardware configuration.

How many storage switching slots does the MDS 9509 have?

The MDS 9509 provides seven switching or services slots within its nine-slot chassis; the remaining two positions accommodate DS-X9530-SF2-K9 Supervisor-2 modules in this bundle. Storage port count follows installed cards rather than being fixed by the chassis PID. Include the card inventory and related optic quantities in the configured purchase order.

What is required for 10G Fiber Channel on the MDS 9509?

10G Fiber Channel on the MDS 9509 uses DS-X9704 four-port switching cards with compatible optics such as the short-reach DS-X2-FC10G-SR transceiver. These components are separate from DS-C9509-2K9. Match the selected optical interface, fiber connection and link distance at both ends, and include card and optic quantities in the configured order.

Can the MDS 9509 aggregate SAN inter-switch links?

The MDS 9509 can aggregate 16 speed-matched physical ISLs into one PortChannel, including ports from different cards. The logical bundle therefore does not need to remain on one card. Plan physical members individually: each still needs an allocated port, compatible optics and cabling, with matching speeds across the group.

What is the difference between DS-C9509-2K9 and DS-C9509?

DS-C9509-2K9 includes two DS-X9530-SF2-K9 Supervisor-2 modules and two DS-CAC-3000W AC supplies, whereas DS-C9509 identifies the chassis-only configuration. Both are discontinued. The bundle suits like-for-like control-and-power replacement; the chassis-only form suits reuse of qualified components when those components are already available and matched to the retained SAN.

What is the difference between DS-C9509-2K9 and DS-C9506-2K9?

DS-C9509-2K9 provides seven switching or services bays, whereas DS-C9506-2K9 provides four in a six-slot chassis. Both bundles are discontinued. The larger director suits buyers retaining more installed cards; the smaller director fits requirements that stay within four data-plane cards and its different chassis footprint.

What is the difference between DS-C9509-2K9 and DS-C9710-V2K9?

DS-C9710-V2K9 includes two DS-X97-SF4-K9 Supervisor-4 modules, whereas DS-C9509-2K9 includes two DS-X9530-SF2-K9 Supervisor-2 modules. The newer bundle is the current endpoint of the replacement chain; the older bundle is discontinued. The former suits migration purchasing, while the latter is a like-for-like legacy control configuration.

How much rack space does the MDS 9509 require?

The MDS 9509 occupies 14RU in a standard equipment rack and measures 623 mm high, 441 mm wide and 468 mm deep. Fully configured weight reaches 78 kg. Allow for cable management and ventilation when confirming cabinet fit; chassis depth including its cable guide is 550 mm.