Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense
Enterprise Clients
Featured Deal
Hand-picked by our procurement team for standout value. This unit is offered at our sharpest price on current stock, verified against live market rates.
Name:
Ready to Ship
Certified Refurbished
Professionally inspected, bench-tested, and firmware-verified, with configurations wiped. Restored to full working order and backed by our warranty.
UCSC-M-V100-04
Cisco UCSC-M-V100-04 UCS VIC 1477 2-Port 40/100G QSFP28 mLOM...
Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense




Enterprise Clients
Built Global. Stocked Local.
Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.
Buyer Protection on Every Order
Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.
Verified By Federal Bodies
Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.
Since 2016, Enterprise-Trusted
Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.
UCSC-M-V100-04 is the Cisco UCS VIC 1477 dual-port 40/100G QSFP28 mLOM Virtual Interface Card for C220 M6, C240 M6, C225 M6 and C245 M6 rack servers. The card presents Ethernet NICs or FCoE HBAs to the host and occupies the mLOM bay rather than a rear PCIe riser. For a Cisco C220 M6 network adapter, this PID fits the dedicated mLOM card bay on the chassis floor and keeps the rear riser slots open for PCIe cards. Its two QSFP28 ports connect to Cisco fabric interconnects or Nexus switch ports at 40 Gbps or 100 Gbps. UCSC-M-V25-04 is the same M6 mLOM generation for buyers who need four 10/25G SFP28 ports instead.
UCSC-M-V100-04 price is is available on request. Get immediate quote.
Request bulk order quote for UCSC-M-V100-04 for additional pricing. Browse the full Cisco UCS VIC 1400 Converged Network Adapters series or explore all Cisco products.
Two 40/100G QSFP28 Ethernet and FCoE ports use a PCIe 3.0 x16 host interface and 2GB DDR3 memory at 1866 MHz. 256 virtual interfaces create independent NIC and HBA personalities, with about eight reserved for internal use. UCSC-M-V100-04 uses the Cisco UCS custom ASIC and manages through UCS Manager, Cisco IMC or Intersight. SR-IOV, usNIC, DPDK, VM-FEX, NetFlow, VXLAN, NVGRE, GENEVE, iSCSI boot, NPIV and RoCEv2 give the host the offload set to match. Back-to-back VIC latency is as low as 1 microsecond, and Nexus switch latency is about 1 to 2 microseconds. 27.9W maximum power sets the slot budget, and the 18.8 mm by 101.3 mm by 159.8 mm card dimensions match the mLOM bay.
UCSC-M-V100-04 is offered new sealed and certified refurbished. New sealed units carry up to 3-year extended warranty, and certified refurbished units carry up to 1 year. Certified refurbished units are inspected and bench-tested in a compatible host; firmware version verified and every port links at rated speed. Order the Cisco UCS VIC 1477 with Cisco QSFP28 optics or QSFP DACs for the far end. Returns are 30 days on every condition; terms apply. Regional stock/RMA covers UK, EU, US and MEA, with RMA with advance replacement, PO accepted and Net-30 for government.
| Key Specs | Key Spec Values |
|---|---|
Ports | 2 x 40/100G QSFP28 |
Fits | C220 M6 / C240 M6 / C225 M6 |
Lifecycle Status | Sales stopped 15 July 2026 |
Form Factor | mLOM, PCIe 3.0 x16 |
Technology | Ethernet / FCoE |
Virtual Interfaces | 256 |
A buyer replacing a failed mLOM in a C220 M6 or C240 M6 needs the C-Series M6 PID, not the M5 mLOM card. The 40/100G QSFP28 ports and mLOM bay must match the installed cabling. Before the PO, confirm the chassis generation and mLOM slot on the asset label.
A team adding 100G uplinks to C225 M6 or C245 M6 servers needs the mLOM form when rear PCIe risers stay reserved for storage or GPU cards. The adapter occupies the mLOM bay and leaves PCIe risers untouched. Before the PO, confirm the host model and QSFP28 cable plan.
A fabric-interconnect refresh using UCS-FI-6536 or UCS-FI-6664 needs 40G or 100G optics and releases that match the selected port speed. The VIC 1477 has no reverse breakout to 4x10G or 4x25G. Before the PO, order Cisco QSFP optics or DACs for each link.
C-Series M5 mLOM
UCSC-M-V100-04 fits C-Series M6 rack servers. C220 M5, C240 M5 and C240 SD M5 use UCSC-MLOM-C100-04 for dual 40/100G QSFP28 mLOM.
10/25G SFP28 cabling
UCSC-M-V100-04 has QSFP28 40/100G ports. C220 M6, C240 M6, C225 M6 and C245 M6 use UCSC-M-V25-04 for four 10/25G SFP28 mLOM ports.
Rear PCIe adapter slot
UCSC-M-V100-04 occupies the mLOM bay. C220 M6 and C240 M6 use UCSC-PCIE-C100-04 when the order calls for a dual 40/100G QSFP28 PCIe card.
Mon–Fri: [09:00-16:00]
Avg. response under 30 mins
| Adapter Type | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card |
| Connector Type | QSFP28 | Internal | QSFP28 | Internal | QSFP28 |
| Data Rate | 100G | 40G | 100G | 40G | 100G |
| Depth | 159.8 mm | 148.6 mm | 146.1 mm | 148.6 mm | 167.6 mm |
| Form Factor | mLOM | Mezzanine | mLOM | mLOM | PCIe Card |
| Height | 18.8 mm | 33.8 mm | 16 mm | 24.4 mm | 13.5 mm |
| Power Consumption | 27.9W maximum | 21W maximum | 28W maximum | 21 W maximum | 28W maximum |
| Width | 101.3 mm | 73.7 mm | 94 mm | 86.4 mm | 63.5 mm |
Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.
New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 90 days, for dependable protection on every order. The exact term is confirmed on your quote, order confirmation and invoice.
If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.
Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.
Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.
Same-day dispatch from regional hubs, free next-day delivery*, fully tracked and insured.
UCSC-M-V100-04 is the Cisco UCS VIC 1477 dual port 40/100G QSFP28 mLOM Virtual Interface Card for C-Series M6 rack servers. The code is the base orderable PID for the adapter. UCSC-M-V100-04= is the spare form, and UCSC-M-V100-04-RF is Cisco Refresh remanufactured.
UCSC-M-V100-04 fits C220 M6, C240 M6, C225 M6 and C245 M6 rack servers. It is a C-Series M6 mLOM card, not the C220 M5 or C240 M5 mLOM. Those M5 systems use UCSC-MLOM-C100-04 for the same 40/100G mLOM role.
A C220 M6 uses UCSC-M-V100-04 for dual 40/100G QSFP28 mLOM connectivity. Other C220 M6 VIC choices in the same mLOM/VIC set are UCSC-M-V5Q50G, UCSC-M-V5Q50GV2, UCSC-M-V5D200G, UCSC-M-V5D200GV2 and UCSC-M-V25-04. Choose the PID that matches port speed, connector and mLOM or PCIe placement.
UCSC-M-V100-04 has two 40/100G QSFP28 Ethernet and FCoE ports, PCIe 3.0 x16 host interface, 27.9W maximum power, and 18.8 mm height by 101.3 mm width by 159.8 mm depth. The card carries 2GB DDR3 memory at 1866 MHz and presents 256 virtual interfaces.
UCSC-M-V100-04 uses two QSFP28 ports rated for 40 Gbps or 100 Gbps Ethernet and FCoE. The far end must match the selected 40G or 100G optic, DAC or switch port. Reverse breakout from the 40/100G ports to 4x10G or 4x25G is not available.
UCSC-M-V100-04 uses Cisco QSFP optics and cables for its 40G and 100G links. 100G choices include QSFP-100G-SR4-S, QSFP-100G-LR4-S, QSFP-100G-DR-S and QSFP-100G-FR-S. 40G choices include QSFP-40G-SR4 and QSFP-40G-LR4. Cisco QSFP-100G-CU1M and QSFP-H40G-CU1M cover short copper runs.
UCSC-M-V100-04 uses the mLOM card bay in C-Series M6 rack servers. On C220 M6, the bay is a x16 PCIe lane location on the chassis floor below PCIe riser slot 1. It does not occupy C220 M6 rear PCIe riser 1, 2 or 3.
UCSC-M-V100-04 requires UCS Manager 4.2(1) minimum for fabric-interconnect operation or standalone Cisco IMC 4.2(1) minimum for direct server management. The management paths are UCS Manager, Cisco IMC and Intersight. RoCEv2 on the VIC 1400/14000 family starts with UCS Manager Release 4.1.
UCSC-M-V100-04 provides SR-IOV, usNIC, DPDK, VM-FEX, NetFlow, Receive Side Scaling, GENEVE, VXLAN and NVGRE features. Storage and fabric functions include FCoE, iSCSI boot, fNIC, NPIV, FC-NVMe and RoCEv2. Back-to-back VIC latency is as low as 1 microsecond.
UCSC-M-V100-04 is the configured base PID for the VIC 1477 mLOM. UCSC-M-V100-04= is the Cisco spare form for the same adapter description. UCSC-M-V100-04-RF is Cisco Refresh remanufactured and is separate from certified refurbished condition. Match the PO line to the required supply path.
UCSC-M-V100-04 provides two 40/100G QSFP28 ports, while UCSC-M-V25-04 provides four 10/25G SFP28 ports. Both are mLOM cards for C220 M6, C240 M6, C225 M6 and C245 M6. Choose UCSC-M-V100-04 for 100G uplinks and UCSC-M-V25-04 for SFP28 cabling.
UCSC-M-V100-04 is the C-Series M6 mLOM PID for C220 M6, C240 M6, C225 M6 and C245 M6. UCSC-MLOM-C100-04 is the same 40/100G mLOM role for C220 M5, C240 M5 and C240 SD M5. The chassis generation decides the order.
UCSC-M-V5D200GV2 moves the C220 M6 mLOM path to two 40/100/200G QSFP/QSFP28/QSFP56 ports, PCIe Gen4 x16, 4GB DDR4 memory and secure boot. UCSC-M-V100-04 stays at two 40/100G QSFP28 ports, PCIe Gen3 x16 and 2GB DDR3 memory. Choose the 200G PID when the fabric and optics match 200G.
Cisco stopped selling UCSC-M-V100-04 on 15 July 2026, and the last ship date was 15 October 2026. Cisco has not announced a last date of support for UCSC-M-V100-04. The PID serves C220 M6, C240 M6, C225 M6 and C245 M6 rack servers.
ORM offers UCSC-M-V100-04 new sealed with up to 3-year extended warranty and certified refurbished with up to 1 year. Certified refurbished units are inspected and bench-tested in a compatible host; firmware version verified and every port links at rated speed. Returns are 30 days on every condition; terms apply.