Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense
Enterprise Clients
Featured Deal
Hand-picked by our procurement team for standout value. This unit is offered at our sharpest price on current stock, verified against live market rates.
Name:
Ready to Ship
Certified Refurbished
Professionally inspected, bench-tested, and firmware-verified, with configurations wiped. Restored to full working order and backed by our warranty.
UCSC-M-V5D200G
Cisco UCSC-M-V5D200G VIC 15238 2-Port 40/100/200G QSFP mLOM...
Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense




Enterprise Clients
Built Global. Stocked Local.
Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.
Buyer Protection on Every Order
Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.
Verified By Federal Bodies
Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.
Since 2016, Enterprise-Trusted
Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.
UCSC-M-V5D200G is the Cisco UCS VIC 15238 dual-port 40/100/200G QSFP/QSFP28/QSFP56 mLOM Virtual Interface Card for UCS C220 M6, C240 M6, C225 M6 and C245 M6 rack servers. The Cisco UCS C220 M6 network adapter position is the mLOM slot, and the PCIe 4.0 x16 host interface carries Ethernet and FCoE to UCS FI 6536, FI 6332 or Nexus switches named for VIC 15238. Cisco UCS VIC 15238 presents dynamically configured NICs and HBAs through UCS Manager, Intersight Managed Mode, Cisco IMC or Intersight policies. Cisco UCS VIC 15237 is the secure-boot replacement with the same 2-port 40/100/200G mLOM role for UCS C-Series M6 racks.
UCSC-M-V5D200G price is is available on request. Get immediate quote.
Request bulk order quote for UCSC-M-V5D200G for additional pricing. Browse the full Cisco UCS VIC 15000 Converged Network Adapters series or explore all Cisco products.
512 virtual adapters and interfaces carry NIC and HBA personalities without SR-IOV dependency from the operating system or hypervisor. 34.4W maximum power draw sets the server power budget, and the card measures 18.8 mm high, 100.1 mm wide and 159.5 mm deep. UCSC-M-V5D200G uses a Cisco UCS custom ASIC with VXLAN, NVGRE, GENEVE, SR-IOV, NetQueue, VMQ/VMMQ, usNIC and DPDK features. 1 microsecond latency applies in back-to-back VIC connections, and 1-2 microseconds applies through Cisco Nexus switches. RoCEv2, NVMe/FC and NVMe/TCP traffic use the same unified fabric. Both ports must run 100 Gbps or 200 Gbps when either port uses those rates; a 40 Gbps port leaves the other port at 40 Gbps, 100 Gbps or 200 Gbps.
New sealed carries up to 3-year extended warranty; certified refurbished carries up to 1 year, and 30 days on every condition. Certified refurbished units are inspected and bench-tested in a compatible host; every port links at rated speed. Cisco stopped selling this adapter on 27 July 2024, and the secure-boot replacement serves refresh purchases. For an M6 spare, specify UCSC-M-V5D200G and match QSFP56, QSFP28 or QSFP cabling to the far end. Regional stock/RMA covers UK, EU, US and MEA, with RMA with advance replacement; PO accepted and Net-30 for government.
| Key Specs | Key Spec Values |
|---|---|
Ports | 2 x 40/100/200G QSFP/QSFP28/QSFP56 |
Fits | UCS C220 M6, C240 M6, C225 M6 |
Lifecycle Status | Cisco stopped selling 27 July 2024 |
Replacement PID | UCSC-M-V5D200GV2 |
Form Factor | mLOM, PCIe 4.0 x16 |
Minimum Software | UCSM/IMM/CIMC 4.2(3) recommended |
A service team has C220 M6, C240 M6, C225 M6 or C245 M6 racks that already use VIC 15238 mLOM cards. The spare must match the mLOM slot, 34.4W power draw and 40/100/200G QSFP cabling before the PO.
An infrastructure team is connecting M6 rack servers to UCS FI 6536 at 40G or 100G direct attach. VIC 15238 maps to that mode, while 4x25G, 25G QSA28, 93180YC-FX3 and 2348 UPQ paths do not take this card.
A server team is running a UCS standalone server through Cisco IMC or Intersight policies to a Nexus switch named for VIC 15238. The far end must match 40G, 100G or 200G optics or cables, and third-party QSFP parts keep the link down.
UCS M7 mLOM order
UCSC-M-V5D200G is the M6 C-Series ordering PID. UCS C220 M7 and UCS C240 M7 use UCSC-M-V5D200G-D instead.
UCS M8 server refresh
VIC 15238 is not for M8 generation servers. UCS C-Series M8 refreshes use the secure-boot replacement UCSC-M-V5D200GV2D.
25G fabric connection
VIC 15238 does not run 4x25G, 25G QSA28, 93180YC-FX3 or 2348 UPQ modes. Use UCSC-M-V5Q50G for those M6 mLOM paths.
B-Series blade slot
UCSC-M-V5D200G is a C-Series mLOM card. UCS B200 M6 uses the blade mLOM adapter UCSB-ML-V5Q10G instead.
Mon–Fri: [09:00-16:00]
Avg. response under 30 mins
| Adapter Type | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card |
| Connector Type | QSFP / QSFP28 / QSFP56 | Internal | SFP56 | Internal | Internal |
| Data Rate | 200G | 40G | 50G | 25G | 25G |
| Form Factor | mLOM | mLOM | mLOM | Mezzanine | mLOM |
Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.
New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 90 days, for dependable protection on every order. The exact term is confirmed on your quote, order confirmation and invoice.
If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.
Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.
Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.
Same-day dispatch from regional hubs, free next-day delivery*, fully tracked and insured.
UCSC-M-V5D200G is the Cisco VIC 15238 2x 40/100/200G mLOM C-Series network adapter. The model name is Cisco UCS VIC 15238. UCSC-M-V5D200G= is the spare form, and UCSC-M-V5D200G-RF is the Cisco-remanufactured form.
UCSC-M-V5D200G fits UCS C220 M6, UCS C240 M6, UCS C225 M6 and UCS C245 M6 rack servers. It is the M6 mLOM PID. UCS C220 M7 and UCS C240 M7 use UCSC-M-V5D200G-D.
A UCS C220 M6 uses UCSC-M-V5D200G when the server needs a VIC 15238 2-port 40/100/200G mLOM adapter. The same C-Series M6 adapter set also includes UCSC-M-V5Q50G, UCSC-P-V5D200G and UCSC-P-V5Q50G for different port and form-factor choices.
UCSC-M-V5D200G has 2 x 40/100/200G QSFP/QSFP28/QSFP56 ports, a PCIe 4.0 x16 host interface, 34.4W maximum power draw and mLOM form factor. The card measures 18.8 mm high, 100.1 mm wide and 159.5 mm deep.
UCSC-M-V5D200G has two external QSFP/QSFP28/QSFP56 ports rated at 40 Gbps, 100 Gbps and 200 Gbps. The far end must match the selected rate and the Cisco transceiver or cable. Both ports must run 100 Gbps or 200 Gbps when either port uses those rates.
UCSC-M-V5D200G works with Cisco QSFP-200G-SR4-S and QSFP-200G-SL4 for 200G links, Cisco QSFP-100G-SR4-S, QSFP-100G-SL4 and QSFP-100G-LR4-S for 100G links, and Cisco QSFP-40G-SR4 or QSFP-H40G-CU cables for 40G links. Third-party QSFP parts keep the link down.
UCSC-M-V5D200G uses the C-Series mLOM slot and presents a PCIe 4.0 x16 host interface. The card is a direct-connection rack server integration adapter. Dual-Wire and SingleWire integration do not apply to this PID.
UCSC-M-V5D200G uses Cisco UCS Manager 4.2(3) or later recommended, Intersight Managed Mode 4.2(3) or later recommended, and Cisco IMC 4.2(3) recommended for standalone servers. Fabric-interconnect operation uses UCS Manager or Intersight Managed Mode policies, and standalone operation uses Cisco IMC or Intersight policies.
UCSC-M-V5D200G supports Ethernet and FCoE on the same unified fabric. RDMA support is RoCEv2, and storage traffic also covers NVMe/FC and NVMe/TCP. The card presents dynamically configured NICs and HBAs to the host.
UCSC-M-V5D200G is the base PID. UCSC-M-V5D200G= is the spare form. UCSC-M-V5D200G-RF is the Cisco-remanufactured form and is separate from certified refurbished condition. Cisco also names UCSC-M-V5D200G-D= and UCSC-M-V5D200GD-RF for the M7 platform form.
UCSC-M-V5D200GV2 is the replacement for UCSC-M-V5D200G. It is Cisco VIC 15237 2x 40/100/200G mLOM C-Series with secure boot. It fits UCS C-Series M6 rack servers, so confirm the server generation before ordering it.
UCSC-M-V5D200GV2 adds secure boot through the Cisco UCS VIC 15237 replacement while keeping the 2-port 40/100/200G mLOM C-Series role. UCSC-M-V5D200G suits like-for-like VIC 15238 sparing in M6 racks; UCSC-M-V5D200GV2 suits refresh purchases that need the replacement PID.
UCSC-M-V5D200G is the 2-port 40/100/200G QSFP mLOM choice, and UCSC-M-V5Q50G is the 4-port 10/25/50G SFP mLOM choice. Choose UCSC-M-V5D200G for higher per-port speed, and choose UCSC-M-V5Q50G for 25G fabric paths or four lower-speed ports.
Cisco stopped selling UCSC-M-V5D200G on 27 July 2024, and the last ship date was 27 October 2024. Cisco has not announced a last date of support for UCSC-M-V5D200G. The adapter serves UCS C220 M6, C240 M6, C225 M6 and C245 M6 rack servers.
ORM offers UCSC-M-V5D200G in new sealed and certified refurbished condition. New sealed carries up to 3-year extended warranty, and certified refurbished carries up to 1 year. Returns are 30 days on every condition; terms apply. PO accepted, Net-30 for government and RMA with advance replacement apply.