Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense
Enterprise Clients
Featured Deal
Hand-picked by our procurement team for standout value. This unit is offered at our sharpest price on current stock, verified against live market rates.
Name:
Ready to Ship
Certified Refurbished
Professionally inspected, bench-tested, and firmware-verified, with configurations wiped. Restored to full working order and backed by our warranty.
UCSC-M-V5Q50GV2
Cisco UCSC-M-V5Q50GV2 VIC 15427 4-Port 10/25/50G SFP56 mLOM...
Trusted by the Highest-Stakes Buyers
Federal agencies and Fortune 500 operations source through ORM Systems.
US Government & Defense




Enterprise Clients
Built Global. Stocked Local.
Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.
Buyer Protection on Every Order
Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.
Verified By Federal Bodies
Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.
Since 2016, Enterprise-Trusted
Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.
UCSC-M-V5Q50GV2 is a Cisco UCS VIC 15427 virtual interface card with four 10/25/50G SFP+/SFP28/SFP56 ports in an mLOM form factor for Cisco UCS C-Series M6 rack servers. The secure-boot VIC presents Ethernet and FCoE interfaces to the host. As a Cisco UCS C220 M6 network adapter, the card sits in the mLOM bay and connects to fabric interconnects or Cisco Nexus top-of-rack switches. Cisco UCS C240 M6, C225 M6 and C245 M6 use the same C-Series M6 ordering PID. The M7/M8 ordering code uses the same adapter hardware, and the supplied PID stays on M6 orders. Before the PO, match the chassis generation and mLOM bay.
UCSC-M-V5Q50GV2 price is is available on request. Get immediate quote.
Request bulk order quote for UCSC-M-V5Q50GV2 for additional pricing. Browse the full Cisco UCS VIC 15000 Converged Network Adapters series or explore all Cisco products.
512 virtual adapters and interfaces let the VIC create NIC and HBA personalities from one card. Four 10/25/50G ports use SFP+, SFP28 or SFP56 media, and the host side is PCIe 4.0 x16. 4 GB DDR4 memory at 3200 MHz and an integrated blower are part of the VIC 15427 assembly. UCSC-M-V5Q50GV2 draws 27.4W maximum, and the card measures 13.5 mm high, 63.5 mm wide and 167.6 mm deep. FCoE, iSCSI boot, VXLAN, NVGRE, GENEVE, SR-IOV, DPDK and usNIC features sit behind the Cisco UCS custom ASIC. RoCEv2 covers NVMe and SMB Direct paths where the operating system stack uses those features. UCSM/IMM 4.3(2c) is the minimum release for VIC 15427 management.
UCSC-M-V5Q50GV2 is offered as new sealed and certified refurbished. Certified refurbished units are inspected and bench-tested in a compatible host, with firmware version verified and every port linked at rated speed. Order the card with Cisco SFP56, SFP28 or SFP+ media for the target link speed, and confirm the M6 generation and mLOM bay before the PO. New sealed carries up to 3-year extended warranty; certified refurbished carries up to 1 year, and returns are 30 days on every condition; terms apply. UK, EU, US and MEA stock and RMA paths carry RMA with advance replacement, PO accepted and Net-30 for government.
| Key Specs | Key Spec Values |
|---|---|
Ports | 4 x 10/25/50G SFP56 |
Fits | UCS C220 M6 / C240 M6 / C225 M6 |
Form Factor | mLOM, PCIe 4.0 x16 host interface |
Technology | Ethernet / FCoE |
Minimum Software | UCSM/IMM 4.3(2c) minimum |
Replaces | UCSC-M-V5Q50G |
A buyer with a failed C-Series M6 mLOM adapter needs the same four SFP56-cage VIC 15427 part to keep service profiles and cabling aligned. The chassis inventory must show an M6 rack server and one mLOM bay before the PO, because the M7 and M8 order code is different.
A buyer adding a C-Series M6 rack server to a UCS Manager domain may need the same mLOM network adapter across C220 M6, C240 M6, C225 M6 and C245 M6 nodes. The far end must match 10 Gbps, 25 Gbps or 50 Gbps ports and Cisco cables.
A buyer connecting rack servers through UCS fabric interconnects needs Cisco cables or transceivers on each SFP cage. UCS Manager integration uses direct connect or SingleConnect paths through fabric interconnects and FEX hardware. Before the PO, match the fabric interconnect generation, port speed and cable PID.
M7 or M8 rack generation
UCSC-M-V5Q50GV2 is the M6 ordering PID; M7 and M8 C-Series rack servers take UCSC-M-V5Q50GV2-D for the same VIC 15427 hardware.
200G per-port requirement
UCSC-M-V5Q50GV2 tops out at 50 Gbps per port; C-Series M6 rack servers needing 40/100/200G mLOM connectivity take UCSC-M-V5D200GV2.
PCIe riser installation
UCSC-M-V5Q50GV2 uses the mLOM bay; C-Series M6 rack servers needing the same 10/25/50G ports in a PCIe slot take UCSC-P-V5Q50G.
Mon–Fri: [09:00-16:00]
Avg. response under 30 mins
| Adapter Type | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card | Virtual Interface Card |
| Connector Type | SFP+ / SFP28 / SFP56 | SFP56 | Internal | QSFP / QSFP28 / QSFP56 | Internal |
| Data Rate | 50G | 50G | 40G | 200G | 25G |
| Form Factor | mLOM | mLOM | mLOM | mLOM | mLOM |
Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.
New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 90 days, for dependable protection on every order. The exact term is confirmed on your quote, order confirmation and invoice.
If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.
Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.
Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.
Same-day dispatch from regional hubs, free next-day delivery*, fully tracked and insured.
UCSC-M-V5Q50GV2 is the Cisco UCS VIC 15427 Quad port 10/25/50G mLOM for Cisco UCS C-Series M6 rack servers. The V2 suffix separates the secure-boot VIC 15427 from the VIC 15428 generation. UCSC-M-V5Q50GV2= is the spare form, and UCSC-M-V5Q50GV2-RF is Cisco-remanufactured.
UCSC-M-V5Q50GV2 fits Cisco UCS C220 M6, C240 M6, C225 M6 and C245 M6 rack servers in the mLOM bay. The M7 and M8 C-Series rack servers use UCSC-M-V5Q50GV2-D for the same VIC 15427 hardware. Before the PO, confirm the generation on the chassis label.
A Cisco UCS C220 M6 uses UCSC-M-V5Q50GV2 for 4x10/25/50G mLOM connectivity. The same C-Series M6 adapter set also includes UCSC-M-V5D200GV2 for 2x40/100/200G mLOM connectivity and UCSC-P-V5Q50G for 4x10/25/50G PCIe connectivity. Choose the mLOM PID when the order needs the motherboard LAN slot.
UCSC-M-V5Q50GV2 carries four 10/25/50G SFP+/SFP28/SFP56 ports, a PCIe 4.0 x16 host interface, 27.4W maximum power and an mLOM form factor. The card measures 13.5 mm high, 63.5 mm wide and 167.6 mm deep. The controller is a Cisco UCS custom ASIC.
UCSC-M-V5Q50GV2 provides four external SFP cages rated for 10 Gbps, 25 Gbps or 50 Gbps per port. The far end must match the selected speed and media family. 50G links use SFP56 media, 25G links use SFP28 media and 10G links use SFP+ media.
UCSC-M-V5Q50GV2 works with Cisco SFP-50G-SR-S, SFP-50G-SL, SFP-25G-SR-S, SFP-25G-SL, SFP-10/25G-CSR-S, SFP-10/25G-LR-S, SFP-10G-T-X, SFP-10G-SR, SFP-10G-SR-S, SFP-10G-LR and SFP-10G-LR-S optics. Copper cable choices include SFP-50G-CU1M, SFP-H25G-CU1M and SFP-H10GB-CU1M for short reaches.
UCSC-M-V5Q50GV2 uses the mLOM bay in Cisco UCS C-Series M6 rack servers. Each server has one mLOM position for this adapter class. PCIe riser slots are separate positions and use PCIe VIC PIDs. Before the PO, confirm that the mLOM bay is empty.
UCSC-M-V5Q50GV2 needs UCSM/IMM 4.3(2c) minimum for VIC 15427 management. Fabric-interconnect and Nexus paths also carry release floors beside the switch choice, with VIC 15427 entries beginning at 4.3.2 for many paths. Management runs through UCS Manager, Cisco IMC or Intersight, depending on the server mode.
UCSC-M-V5Q50GV2 handles Ethernet and FCoE on the same four ports. The VIC 15000 feature set includes iSCSI boot, eNIC, fNIC, NPIV, VXLAN, NVGRE, GENEVE, SR-IOV, DPDK and usNIC. RoCEv2 covers NVMe over RoCEv2 and SMB Direct paths where the host operating system stack uses those functions.
UCSC-M-V5Q50GV2 replaces UCSC-M-V5Q50G for Cisco UCS C-Series M6 rack servers. The replacement changes the 4x10/25/50G mLOM adapter from VIC 15428 to secure-boot VIC 15427. The older UCSC-M-V5Q50G sale date ended on 27 July 2024, so new M6 orders use the V2 PID.
UCSC-M-V5Q50GV2 is the M6 C-Series rack-server ordering PID, while UCSC-M-V5Q50GV2-D is the M7 and M8 C-Series rack-server ordering PID. The VIC hardware and operation are the same. Choose the supplied PID for M6 chassis orders and the -D PID for M7 or M8 chassis orders.
UCSC-M-V5Q50GV2 is a four-port 10/25/50G SFP56 mLOM adapter, while UCSC-M-V5D200GV2 is a two-port 40/100/200G QSFP56 mLOM adapter. Both serve Cisco UCS C-Series M6 rack servers. Choose UCSC-M-V5Q50GV2 for more SFP-family ports and UCSC-M-V5D200GV2 for higher per-port bandwidth.
UCSC-M-V5Q50GV2 uses the mLOM bay, while UCSC-P-V5Q50G uses a PCIe riser slot. Both provide four 10/25/50G SFP-family ports for Cisco UCS C-Series M6 rack servers. Choose the mLOM PID for the motherboard LAN position and the PCIe PID for an add-in slot.
Cisco has not announced an end-of-sale date for UCSC-M-V5Q50GV2. The adapter serves Cisco UCS C-Series M6 rack servers and replaces UCSC-M-V5Q50G, whose end-of-sale date was 27 July 2024. The M7 and M8 rack-server ordering PID is separate from this M6 page.
ORM offers UCSC-M-V5Q50GV2 as new sealed and certified refurbished. New sealed carries up to 3-year extended warranty, and certified refurbished carries up to 1 year. Certified refurbished units are inspected and bench-tested in a compatible host. Returns are 30 days on every condition; terms apply.