Name:

UCSC-MLOM-C100-04

Description:
Cisco UCSC-MLOM-C100-04 UCS VIC 1497 2-Port 40/100G QSFP28 mLOM Virtual Interface Card for C220 M5 and C240 M5
Rating:
0(0)

Added to cart times recently

Availability:

Ready to Ship

Brand:
Cisco
GTIN:
0889728131346
Condition:
Warranty:
90Up to 90 days warranty
Price:

$951.29

Quantity:

1
100% Genuine Guaranteed
Global Delivery
Business Terms / PO Accepted

Protect Your Shipment for Just 1%:

Up to $5,000 Coverage

Eligible shipments can be insured for up to $5,000 for added protection.

1% Flat Insurance Rate

Coverage costs just 1% of the insured value for affordable shipping protection.

Easy Online Claims

Submit claims online if your shipment is lost, stolen, or damaged.

4.3

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow
ucsc-mlom-c100-04 cisco ucsc-mlom-c100-04 ucs vic 1497 2-port 40/100g qsfp28 mlom virtual interface card for c220 m5 and c240 m5
4.3

3 Year Extended Warranty

arrow

Same-day Shipping

arrow

30-Day Money Back Guarantee

arrow

Need Additional Discount on Product?

Request a quote below - Get Exclusive Pricing and Support.

Qty:

Exclusive Bulk Discounts tailored to your order size

Priority Processing with a dedicated account manager

Fast Response: Get your custom quote within 30 minutes during business hours

Out of Hours: Holiday requests get priority handling the next business day

UCSC-MLOM-C100-04

Original Stock
Ready to Ship
Certified Refurbished

Cisco UCSC-MLOM-C100-04 UCS VIC 1497 2-Port 40/100G QSFP28 m...

$951.29

Get a Quote

Trusted by the Highest-Stakes Buyers

Federal agencies and Fortune 500 operations source through ORM Systems.

US Government & Defense

  • United States Army
  • United States Embassy
  • United States Marine Corps
  • Bureau of Alcohol, Tobacco, Firearms and Explosives

Enterprise Clients

  • Novartis
  • Siemens Healthineers
  • ExxonMobil

Built Global. Stocked Local.

Regional teams and 25+ distribution partners keep stock near you and accountability in your time zone.

4Global Offices
25+Distribution Points
100+Countries Served

Buyer Protection on Every Order

Pay by PayPal or Revolut with full chargeback rights. Order on PO terms, Net-30 for government.

Verified By Federal Bodies

Every registration we claim is public record — check our federal contractor status yourself before you spend a dollar.

  • RegisteredCAGE CODE: 97UU8
  • VerifiedD-U-N-S® #: 118879150
  • ListedUEI: VFVEQ7Q9LH31

Since 2016, Enterprise-Trusted

Ten years serving buyers who audit their vendors. From federal agencies to 20,000+ enterprise clients worldwide.

10+Years Operating
20,000+Clients Served
150K+SKUs Available

40/100G mLOM Connectivity For M5 Rack Servers

UCSC-MLOM-C100-04 is a Cisco UCS VIC 1497 virtual interface card with 2 x 40/100G QSFP28 ports in the mLOM form factor for C220 M5, C240 M5 and C240 SD M5 servers. It presents NICs or HBAs to the host for Ethernet or FCoE service profiles. The Cisco C220 M5 network adapter uses an internal mLOM x16 location, so riser slots stay available for PCIe cards. The ports connect to Fabric Interconnects or Nexus switches with Cisco QSFP optics or cables. UCSC-PCIE-C100-04 is the PCIe sibling for riser 1 or 2 and broader C-Series M5/M6 host coverage.

UCSC-MLOM-C100-04 price for new stock is $1,276.80. UCSC-MLOM-C100-04 refurb price is $951.29. UCSC-MLOM-C100-04 is in stock and available for free next-day delivery. (terms applied)

Request bulk order quote for UCSC-MLOM-C100-04 for additional pricing. Browse the full Cisco UCS VIC 1400 Converged Network Adapters series or explore all Cisco products.

Technical Details

256 virtual interfaces let service profiles create independent NICs and HBAs; about 8 interfaces are reserved for internal use, and the OS or hypervisor can reduce the usable count. PCIe 3.0 x16 host connectivity feeds the Cisco UCS custom ASIC. 28W maximum power and 16 mm x 94 mm x 146.1 mm sizing match the VIC 1497 mLOM envelope. UCSC-MLOM-C100-04 supports SR-IOV, usNIC, iSCSI boot, eNIC, fNIC, DPDK, NetFlow, NPIV, VM-FEX, GENEVE, VXLAN, NVGRE, PFC and 9KB jumbo frames. Back-to-back VIC connections have latency as low as 1 microsecond, and Nexus switch paths run at about 1 to 2 microseconds. RoCEv2 runs with Windows Server 2019 NDKPI Mode 1 and Mode 2, IPv4, IPv6 and Linux; UCS Manager 4.1 adds NVMeoF with RDMA.

Ordering

UCSC-MLOM-C100-04 is offered as new sealed or certified refurbished for C-Series M5 sparing. Certified refurbished units are inspected and bench-tested in a compatible host; the board, connector and bracket are inspected, recognized by a compatible host and every port links at rated speed. Order the mLOM card with Cisco QSFP optics or QSFP cables that match 40G or 100G switch ports. New carries up to 3-year extended warranty; certified refurbished carries up to 1 year, and returns are 30 days on every condition. UK, EU, US and MEA stock/RMA with advance replacement serves PO accepted and Net-30 for government buyers.

Buying Notes

Buying NotesKey Specs

mLOM placement

UCSC-MLOM-C100-04 installs in the mLOM x16 location, not a riser slot. C220 M5 and C240 M5 systems keep PCIe riser slots available for plug-in VICs, HBAs or NICs.

Optics and cables

Links fail with third-party transceivers or cables. Order Cisco QSFP parts that match the far end, for example QSFP-100G-SR4-S, QSFP-100G-LR4-S, QSFP-H40G-CU1M or QSFP-100G-CU1M.

Software floor

UCSC-MLOM-C100-04 needs UCS Manager 4.0(2c) minimum with VIC firmware 5.0(2b), or standalone 4.0(2) minimum with VIC firmware 5.0(2b).

Lifecycle and forms

Cisco stopped selling UCSC-MLOM-C100-04 on 30 October 2023. UCSC-MLOM-C100-04= is the Cisco spare form, while certified refurbished is ORM's tested condition.

Key Specs

Key SpecsKey Spec Values

Ports

2 x 40/100G QSFP28

Fits

C220 M5, C240 M5, C240 SD M5

Lifecycle Status

End of sale 30 October 2023

Form Factor

mLOM x16

Technology

Ethernet and FCoE

Virtual Interfaces

256

UCSC-MLOM-C100-04 Specifications

Manufacturer Part Number
UCSC-MLOM-C100-04
Brand
Cisco
Model Name
Cisco UCS VIC 1497
Adapter Type
Virtual Interface Card
Product Line
UCS C-Series
Compatible With
UCS C220 M5 / UCS C240 M5 / UCS C240 SD M5
Slot
mLOM x16
Technology
Ethernet / FCoE
Data Rate
100G
Supported Speeds
40 Gbps / 100 Gbps
Port Count
2
Ports
2 x 40/100G QSFP28
Connector Type
QSFP28
Form Factor
mLOM
Host Interface
PCIe 3.0 x16
Controller
Cisco UCS custom ASIC
Virtual Interfaces
256
FCoE Support
Yes
RDMA Support
RoCEv2
Offloads and Features
SR-IOV / usNIC / iSCSI boot / VM-FEX / DPDK / NetFlow / NPIV / Receive Side Scaling / GENEVE / VXLAN / NVGRE / PFC / 9KB jumbo frames
Boot Support
iSCSI Boot
Supported Transceivers
QSFP-100G-SR4-S / QSFP-40/100-SRBD / QSFP-100G-SR1.2 / QSFP-100G-LR4-S / QSFP-100G-SL4 / QSFP-100G-DR-S / QSFP-100G-FR-S / QSFP-100G-SM-SR / QSFP-100G-CWDM4-S / QSFP-100G-PSM4-S / QSFP-40G-SR4 / QSFP-40G-LR4
Management
UCS Manager / Intersight
Minimum Software
C220 M5: UCS Manager 4.0(2c) minimum with VIC firmware 5.0(2b) / C240 M5: UCS Manager 4.0(2c) minimum with VIC firmware 5.0(2b) / C240 SD M5: UCS Manager 4.0(2c) minimum with VIC firmware 5.0(2b) / Standalone 4.0(2) minimum with VIC firmware 5.0(2b)
Operating System Support
VMware vSphere / Microsoft Windows / Red Hat Enterprise Linux / Citrix XenServer / SUSE Linux Enterprise Server / Ubuntu
Power Consumption
28W maximum
Height
16 mm
Width
94 mm
Depth
146.1 mm

Best For

Failed mLOM

A buyer replacing a failed mLOM in a C220 M5, C240 M5 or C240 SD M5 keeps the server on the UCS VIC 1497 form factor. Specify UCSC-MLOM-C100-04 and match the chassis label to the M5 generation before the PO.

Server Expansion

A buyer adding VIC capacity to a C220 M5 or C240 M5 can place this card in the mLOM slot while plug-in VICs use riser slots. Confirm the CPU count and riser layout on the running inventory before the PO.

Fabric Interconnect Attach

A buyer attaching M5 rack servers to UCS-FI-6332, UCS-FI-6332-16UP, UCS-FI-6536 or UCS-FI-6664 fabric uses Cisco QSFP optics or cables per link. Specify the 40G or 100G far-end port speed before the PO.

Not Suitable If

M6 mLOM upgrade

UCSC-MLOM-C100-04 fits C220 M5, C240 M5 and C240 SD M5. C220 M6, C240 M6, C225 M6 and C245 M6 take UCSC-M-V100-04.

PCIe riser installation

UCSC-MLOM-C100-04 uses the mLOM location and does not occupy riser 1 or 2. A riser installation takes UCSC-PCIE-C100-04.

Native 10/25G SFP28 ports

UCSC-MLOM-C100-04 has no reverse-breakout to 4x10G or 4x25G. C220 M5, C240 M5 and C240 SD M5 use UCSC-MLOM-C25Q-04 for 10/25G SFP28.

Product Comparison Table

Cisco UCSC-MLOM-C100-04 UCS VIC 1497 2-Port 40/100G QSFP28 mLOM Virtual Interface Card for C220 M5 and C240 M5UCSC-MLOM-C100-04Cisco UCSB-MLOM-40G-04 VIC 1440 1-Port 40G mLOM Virtual Interface Card for UCS B200 M6 and B200 M5UCSB-MLOM-40G-04Cisco UCSC-PCIE-C100-04 UCS VIC 1495 2-Port 40/100G QSFP28 PCIe Virtual Interface Card for C125 M5 and C220 M5UCSC-PCIE-C100-04Cisco UCSC-PCIE-C25Q-04 VIC 1455 4-Port 10/25G SFP28 PCIe Virtual Interface Card for C225 M6 and C240 M6UCSC-PCIE-C25Q-04Cisco UCSB-VIC-M84-4P VIC 1480 1-Port 40G Internal Mezzanine Virtual Interface Card for UCS B200 M5 and UCS B200 M6UCSB-VIC-M84-4P
Adapter TypeVirtual Interface CardVirtual Interface CardVirtual Interface CardVirtual Interface CardVirtual Interface Card
Connector TypeQSFP28InternalQSFP28SFP28Internal
Data Rate100G40G100G25G40G
Depth146.1 mm148.6 mm167.6 mm167.6 mm148.6 mm
Form FactormLOMmLOMPCIe CardPCIe CardMezzanine
Height16 mm24.4 mm13.5 mm13.5 mm33.8 mm
Power Consumption28W maximum21 W maximum28W maximum27.4W maximum21W maximum
Width94 mm86.4 mm63.5 mm63.5 mm73.7 mm

Compliance & Warranty

ISO 27001
ISO 45001
RoHS
REACH
FCC
CE
UKCA
VCCI
ISO 9001
ISO 14001

100% Genuine Product Guarantee

Every unit is authentic, sourced through trusted and authorised channels, and serial-verified on request. Genuine networking and IT hardware, guaranteed, or your money back.

Up to 3-Year Warranty Coverage

New products are backed by up to 3 years of extended warranty, and certified refurbished units by up to 90 days, for dependable protection on every order. The exact term is confirmed on your quote, order confirmation and invoice.

Hassle-Free RMA & Returns

If a unit ever falls short, our streamlined RMA process gets a replacement to you fast, with advance replacement available to keep your network running. No jargon, no runaround.

Rigorously Tested & Quality Assured

Every device is inspected, bench-tested, and firmware-verified, with configurations wiped before dispatch. Additional testing can be arranged to confirm full working condition on request.

Expert Technical Support

Our specialists assist with compatibility, configuration, licensing, and installation, before and after you buy. Real hardware expertise, whenever you need it.

Fast Global Delivery

Same-day dispatch from regional hubs, free next-day delivery*, fully tracked and insured.

Questions & Answers

What is UCSC-MLOM-C100-04?

UCSC-MLOM-C100-04 is the Cisco UCS VIC 1497 Dual Port 100G QSFP28 CNA mLOM. Cisco UCS VIC 1497 is a dual-port 40/100G QSFP28 mLOM virtual interface card for C-Series M5 rack servers. UCSC-MLOM-C100-04= is the Cisco spare form.

What servers does UCSC-MLOM-C100-04 fit?

UCSC-MLOM-C100-04 fits UCS C220 M5, UCS C240 M5 and UCS C240 SD M5 rack servers. The card uses the mLOM x16 location. M6 rack servers do not take this PID; C220 M6, C240 M6, C225 M6 and C245 M6 take UCSC-M-V100-04.

What network adapter does a UCS C220 M5 use?

A UCS C220 M5 uses UCSC-MLOM-C100-04 for dual 40/100G QSFP28 mLOM service. Other C220 M5 mLOM choices are UCSC-MLOM-C25Q-04 for quad 10/25G SFP28, UCSC-MLOM-C40Q-03 for dual 40G QSFP+ and UCSC-MLOM-IRJ45 for quad 1GBase-T.

What are the UCSC-MLOM-C100-04 specifications?

UCSC-MLOM-C100-04 has 2 x 40/100G QSFP28 ports, PCIe 3.0 x16 host connectivity, 28W maximum power and 16 mm x 94 mm x 146.1 mm dimensions. The card is an mLOM virtual interface card and presents NICs or HBAs for Ethernet or FCoE.

What ports and speed does UCSC-MLOM-C100-04 have?

UCSC-MLOM-C100-04 has two QSFP28 ports rated for 40 Gbps or 100 Gbps per port. The far end must match the selected 40G or 100G mode with Cisco QSFP optics, passive copper cables or active optical cables.

Which transceivers and cables work with UCSC-MLOM-C100-04?

UCSC-MLOM-C100-04 works with Cisco QSFP parts for 40G and 100G links. Common 100G optic choices are QSFP-100G-SR4-S, QSFP-40/100-SRBD, QSFP-100G-LR4-S and QSFP-100G-DR-S. Cable choices include QSFP-100G-CU1M, QSFP-100G-CU2M, QSFP-100G-CU3M and QSFP-100G-AOC10M.

Which slot does UCSC-MLOM-C100-04 use?

UCSC-MLOM-C100-04 uses the mLOM x16 location inside C220 M5, C240 M5 and C240 SD M5 servers. It does not consume riser 1 or riser 2. A C240 M5 with two GPUs still needs an mLOM VIC for UCS Manager discovery.

What software does UCSC-MLOM-C100-04 need?

UCSC-MLOM-C100-04 needs UCS Manager 4.0(2c) minimum with VIC firmware 5.0(2b) or standalone 4.0(2) minimum with VIC firmware 5.0(2b). Recommended levels are UCS Manager 4.0(4e) with VIC firmware 5.0(3d) and standalone 4.0(4h) with VIC firmware 5.0.3(d).

Does UCSC-MLOM-C100-04 support RDMA and FCoE?

UCSC-MLOM-C100-04 supports RoCEv2, FCoE, FC-NVMe and NVMeoF with RDMA. Feature support also covers SR-IOV, usNIC, iSCSI boot, VM-FEX, DPDK, NetFlow, NPIV, Receive Side Scaling, GENEVE, VXLAN, NVGRE, PFC and 9KB jumbo frames.

How do UCSC-MLOM-C100-04 ordering variants work?

UCSC-MLOM-C100-04 is the base orderable PID for the Cisco UCS VIC 1497 mLOM card. UCSC-MLOM-C100-04= is the Cisco spare form. Cisco remanufactured PIDs are distinct from ORM certified refurbished condition, which is inspected and bench-tested before sale.

What is the difference between UCSC-MLOM-C100-04 and UCSC-PCIE-C100-04?

UCSC-MLOM-C100-04 is the mLOM version for C220 M5, C240 M5 and C240 SD M5. UCSC-PCIE-C100-04 is the PCIe version for riser 1 or 2 and adds broader C-Series M5 and M6 host coverage. Choose by slot first.

What is the difference between UCSC-MLOM-C100-04 and UCSC-MLOM-C25Q-04?

UCSC-MLOM-C100-04 provides two QSFP28 ports at 40G or 100G. UCSC-MLOM-C25Q-04 provides four SFP28 ports at 10G or 25G for the same C220 M5, C240 M5 and C240 SD M5 hosts. Choose by switch port type.

What is the difference between UCSC-MLOM-C100-04 and UCSC-M-V100-04?

UCSC-MLOM-C100-04 is the 40/100G mLOM card for C220 M5, C240 M5 and C240 SD M5. UCSC-M-V100-04 is the 40/100G mLOM card for C220 M6, C240 M6, C225 M6 and C245 M6. Choose by server generation.

What is the lifecycle status of UCSC-MLOM-C100-04?

Cisco stopped selling UCSC-MLOM-C100-04 on 30 October 2023. Last ship date was 28 January 2024. Cisco has not announced a last date of support for UCSC-MLOM-C100-04. C220 M5, C240 M5 and C240 SD M5 service ends on 31 October 2028.

Does ORM sell UCSC-MLOM-C100-04 new and refurbished?

ORM sells UCSC-MLOM-C100-04 in new sealed and certified refurbished condition. New carries up to 3-year extended warranty, certified refurbished carries up to 1 year, and returns are 30 days on every condition. PO accepted, Net-30 for government and RMA with advance replacement apply.